Performance tests and uncertainty analysis of tipping bucket rain gauge

전도형 강수량계의 성능시험 및 불확도 분석

  • Published : 2018.05.31

Abstract

Precipitation has a wide range of applications, such as the management and operation of dams and rivers, supply of dranking water for urban and industrial complex, farming and fishing, forest greening, and safety management. In order to prepare for disasters and to obtain economical effects in case of flood damage, it is necessary to measure accurate precipitation. In this study, we carried out the characteristics tests for various types of rainfall gauge using integrated verification system, which can analyze the performance of collective type rainfall gauge. The uncertainty for tipping bucket rain gauge was 0.2887 mm. Therefore, it can be seen that the uncertainty is calculated differently depending on the characteristics of the rainfall gauges. The uncertainty is also influenced greatly by the resolution.

강수량의 계측은 댐 및 하천의 안정적인 운영 및 유지관리, 도시 및 산업단지의 먹는 물 및 용수공급, 농어촌의 영농 및 산림녹화 등 광범위한 범위에서 필요로 하고 있으며, 재난재해를 대비하고 강우 발생시 경제적인 효과를 얻기 위해서는 정확한 강수량의 측정이 필요하다. 본 연구에서는 강수량계의 성능을 분석할 수 있는 교정시스템을 이용하여 전도형 강수량계에 대한 강우강도 20 ~ 100 mm/h에 대한 특성시험을 실시하였으며, 측정값은 19.30 ~ 19.59 mm, 오차율은 0.31 ~ 0.35 mm로 측정되었으며, 불확도는 0.2887 mm로 산출되었다. 이러한 특성시험을 통하여 기상 및 수문 관측 데이터의 신뢰성을 확보하고자 하였다.