Comparative Experiment to Determine the Activation Factor of Lead dioxide by Kinds in Measuring the Concentration of Sulfur oxides in the Atmosphere by $PbO_2$ Cylinder Method

사용시약별로 본 이산화연법에 의한 대기중 황산화물의 비교측정및 자동측정 성적과의 비교

  • 최덕일 (국립보건연구원 위생부)
  • Published : 1975.02.01

Abstract

This experiment Was carried out under two points of view, from May 1st to the end of 1973. One was the comparative determination of the activation factor of Lead dioxide by kinds in measuring of Sulfur oxides concentration by $PbO_2$ cylinder method, and the other was the comparison that result with the record of auto analyzer. Five measuring sites were selected out of Seoul City. Three kinds of Lead dioxide made in Japan (B,C and D) were compared with Standard $PbO_2$ (A for use in Determination of Sulphur in the atmosphere, purity 99% up) made in British Institution, and monthly measuring was conducted at every sampling site. The recording by auto analyzer (Beckman Model 906-A $SO_2$ Analyzer) was conducted once or twice a month for 24 hours at each sampling site during the same period. And some significant results were obtained. 1. In comparative experiments to determine the activation degree of three kinds of Lead dioxide (B,C and D), the obtained correction factor of B reagent was 1.09, 1.16 in C and 1.30 in D against Standard $PbO_2$ (A). Therefore, it should be in need of standardization or clear statement about the reagents for use, in determination sulfur oxides by $PbO_2$ cylinder method. 2. Generally, the concentration of Sulfur dioxide by wilkins' convertion method from $SO_3$ showed about 20-30% higher than those by Auto analyzer.