Experimental Investigation on Air-Distribution in a Water-Flowing through a G1-Rod Bundle with Helical Spacers

  • Published : 1978.06.01

Abstract

The object of this study was to obtain data on air-distributions in two-phase up flow in vertical rod-bundle test-section. The test-section in this study was a hexagonal shaped 61-rod bundle where each rod was wrapped with helical spacers. The variables were flow rates of air and water and air inlet positions. Experimental data were obtained at the outlet of the test-section. The experiments were performed in two parts. Firstly, data were taken at increasing flow rates of air keeping water flow rates constant, and secondly, at simultaneous increase of air and water flow rates. At each flow condition, air supply position could be changed to 4 different positions. Data obtained by electrical void-needle technique were analyed and are presented here in graphical forms for comparison. The results of this study demonstrate qualitatively that air-distribution tends to be more uniform as water flow rates are increased. The air supply positions have noticeable effects on the pattern of air-distribution.

본 연구의 목적은 수직 연료봉 집합체에서 물-공기 2상 유동일 경우 공기분포현상에 관한 실험적 데이타를 얻는데 있다. test-section은 6각형, 61개의 연료봉 집합체로 구성되며, 각 연료봉은 helical spacers로 감겨져 있고, 사용되는 유체는 공기와 물이다. 실험은 크게 2부분으로 나누어서 물의 유량을 일정하게 하고 공기의 유량을 증가시킬 경우와 물자 공기의 유량을 동시에 증가시킬 경우의 공기분포현상에 관해 실시하였다. 공기는 4구멍을 통해 각각 주입시켰다. 보이드율의 측정은 전기적 Void-needle 방법을 적용하였으며 그 결과는 도표를 통해 보여주고 있다. 이 실험의 결과로써 물의 유랑을 증가시킬 수록 공기분포는 균일하게 되며, 공기 공급 위치는 공기분포에 큰 영향을 미치고 있음이 입증되었다.

Keywords