Feasibility Study of the Combustible Gab Control System Following a LOCA

냉각재 상실사고시 가연성 가스제거 계통의 타당성 조사

  • Published : 1984.12.01

Abstract

The feasibility of not employing recombiners rather using the postaccident Purge system alone to control hydrogen concentration in the containment following a LOCA, is analyzed in this paper. For this study, the hydrogen concentration in the containment, hydrogen removal through the purge system, and additional off-site dose due to hydrogen purge were calculated. The economic justification of a hydrogen recombiner system (2 recombiners) was also investigated by using the cost benefit concept. As a result, the purge system is sufficient to maintain the hydrogen concentration at a safe level without hydrogen recombiners, and it meets the dose limit requirements set forth in 10 CFR part 100. A hydrogen recombiner system would be justified based on cost-benefit concept for common use in a site with 4 units or more.

본 연구에서는 냉각수 상실사고(LOCA)시 격납용기내의 수소농도를 제어하기 위해 수소재결합기 없이 수소 퍼지계통만을 사용할 때의 타당성을 분석하였다. 이 타당성 연구를 위해 격납응기내의 수소농도, 수소퍼지 계통의 수소제거, 그리고 퍼지로 인한 추가소외 선량이 계산되었다 또한 비용-편익 개념을 사용하여 수소 재결합기 계통(2대의 재결합기 설치)의 경제성을 분석하였다. 분석결과, 수소퍼지 계통은 수소 재결합기 없이도 수소농도를 제어하기에 충분하며, 10 CFR 100에 있는 선량 제한치를 만족시키고 있었다. 비용-편익 개념에 의하면 수소 재결합기 계통은 동일부지내에 있는 4∼6기의 발전소에 공용될 때 경제성이 있는 것으로 입증되었다.