Crosstalk Compatibility between Different Transmission Modes Operating in a Same Cable Sheath

동일 Cable 뭉치에서 동작하는 이종 디지탈 전송시스템 간의 누화측면에서의 호환성 고찰

  • Published : 1988.02.01

Abstract

Installation of the digital carrier system is increased rapidly in the telecommunication network, and most of systems are operating over a twisted pair conductor. Many systems are accommodated in multipair cable for their economical installation, therefore we must consider tha crosstalk interference between digital systesm. This paper considers the calculation method which determine crosstali interference between signals in multipair. And the transmission margin at a certain error rate is analyzed considering crosstalk power. Finally, this paper estimates the crosstalk noise susceptibility of 2.048Mbps relative to 1.544Mbps PCM system and 1.544Mbps relative to 2.048Mbps PCM system, and then considers the methos which both systems can operate together in a same cable.

원거리 통신망의 디지탈화가 급격히 이루어지고 있다. 이들 디지털 시스템에는 경제성을 고려하여 비틀어 꼰 금속도체쌍을 다중화시켜 사용한다. 이와 같이 다중화된 케이블 뭉치를 사용하는 관계로 전송신호 상호간에 누화간섭이 발생한다. 따라서 본 논문에서는 다중쌍 내 전송신호가 누화간섭을 계산하는 방법을 연구해서 누화간섭전력에 대한 시스템의 전송오차마진을 분석했다. 마지막으로 1.544Mb/s와 2.048Mb/s PCM 시스템의 상호누화잡음훼손도를 계산해서 동일 케이블내 혼용 방법을 제시하였다.

Keywords