A study of estimation for excess attenuation of Noise propagated on the ground

지표면상을 전파하는 소음의 초과감쇠 산정방법에 관한 연구

  • 오재응 (한양대학교 정밀기계공학과) ;
  • 김동규 (한양대학교 정밀기계공학과) ;
  • 임동규 (조선대학교 우주공학과)
  • Published : 1988.04.01

Abstract

This study is to explain the characteristic of excess attenuation on the ground through the outdoors experiment about noise propagation and the reduced model experiment of acoustic. The outdoors experiment on the attenuation of noise propagation was tried with the small engine that had large acoustic output, and then it was conformed that there was relationship between the excess attenuation calculated by measurement from distance attenuation and Log(D/(Hs+Hr)). As a result, it was found that the attenuation of noise propogation depended upon the direction of the wind and frequency and was regressed in a straight line. And the numerical values of excess attenuation on the ground could be calculated by regarding Log(D/(Hs+Hr)) as a parameter with an airing resistance $\sigma$. It was found that when the mean square error between the excess attenuation calculated by measurement and the value calculated by a fomula $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ about optional $\sigma$ was least, the optimal decision of u was made. As the characteristic of model is the model experiment on a reduced scale of 1 to 40, It was conformed that it corresponds enough with the measurement value with measuring the distance attenuation in the large anecoic chamber.

본 연구는 소음전파에 대한 옥외실험과 축적 음향모형실험에 의해서 지표면에 의한 초과감쇠 특징을 밝힌 것으로써, 옥외실험에 의한 소음전파감쇠는 음향출력이 큰 소형엔진을 사용하여, 거리감쇠로부터 산출한 실측의 초과감쇠와 Log(D/(Hs+Hr))의 관계를 확인했다. 그 결과 소음전파감쇠는 풍향, 주파수에 따라 다르며 직선회귀 된다는 것을 알 수 있었다. 그리고, 지표면상의 초과감쇠치는 통기저항을 이용해서 Log(D/Hs+Hr))을 파라미터로써 구할 수 있었고, 가장 적당한 통기저항$\sigma$는 실측의 초과감쇠치와 임의의 $\sigma$에 대한 $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ 식의 평균자승 오차가 가장 적어질 때 결정된다. 모형의 지표로써 축척 1/40의 모형실험으로, 큰 무향실내에서 거리감쇠의 측정을 한 결과, 실측치와의 대응이 충분하다는 것을 확인했다.

Keywords