A study on ignition delays of sprays using a shock tube

충격파관을 이용한 분무연료의 착화지연에 관한 연구

  • 정진도 (충남대학교 대학원, 기계공학과) ;
  • 류정인 (충남대학교 대학원, 기계공학과) ;
  • 수곡행부 (오사카대학 기초공학부 화학공학과)
  • Published : 1989.12.01

Abstract

A shock tube technique was developed in which a freely falling droplets column produced by an ultrasonic atomizer was ignited behind reflected shock. In the present study, the effects of turbulent mixing on the ignition delay of a cetane was decided, also, ignition process was investigated. For the purpose of disturbance of droplets column and mixing, authors installed turbulent lattice in shock tube. Usually, the ignition delay is so called Arrhenius plot which found break point in the Arrhenius plot on the high temperature side. The rate of misfiring increased rapidly below 1080K, but ignition took place from 838k and luminous flame was seen to spread over the whole section by turbulent lattice. Length, from end plate to turbulent lattice, was varied with 60,40,20mm. Also, ignition process was detected by Photo transistor. As a result, it was found that physical factors changed ignition delay greatly and turbulent mixing had a considerable effects in the ignition process.

Keywords