B-Scan Image Processing Technique by Using Ultrasonic Microscope System

초음파 현미경 시스템에 의한 B-스캔 영상처리 기술

  • Published : 1990.12.01

Abstract

In this paper, ultrasonic microscope system has been constructed with the small aperturre acoustic lens and the angle controller, and the new type of B-scanultransonic imaging has been analyzed. The system with small aperture lens was used to detect flaw existing within the thick specimen and its resolution was in the range of one wavelength at interior plane of sample. The anle controller was used to excited surface acoustic wave or shear wave. In order to obtain B-scan image of the flaw existig at interior of solids, shear wave has been excited and backscattering signals from the flaw have been processed. In experimental results, B-scan ultransonic images have been obtain from the flaws of varable shape and measured flaw size from the images has been in good agreement with practical size in the range of 10% error.

Keywords