A Study on Function Recognition of EMG Signal Using LPC Cepstrum Coefficients

LPC 켑스트럼 계수를 이용한 EMG 신호의 기능 인식에 관한 연구

  • Published : 1990.02.01

Abstract

In this study, eight function discrimination and recognition of the EMG signal from the biceps and triceps of 4 subjects were executed, using the Euclidean and weighted cepstral distance measure with LPC cepstrum coefficients. In case of Euclidean cepstral distance measure, as the number of LPC cepstrum coefficients was increased in 8, 10, 12, 14 the recognition rates of functions are 94.69, 95.63, 96.56, and 96.88[%], respectively, but increasing rates of recognition were inclined to decrease. In case of weighted cepstral distance measure, when the number of LPC cepstrum coefficients was 8, 10, 12 and 14, the recognition rates of functions were 91.88, 95, 99.69, and 96.63[%], respectively.

본 논문에서는 3전극법으로 피검자의 이두박근과 삼두박근에서 검출한 표면 근전도 신호를 LPC 켑스트럼 계수를 이용하여 유클리드 및 가중 켐스트럼 거리 측정법을 통하여 8가지 팔 운동에 대한 기능분리 및 판별 인식에 관한 실험을 하였다. 유클리드 켑스트럼 거리 측정법의 경우,계수의 수가 8,10,12,14 등으로 증가함에 따라 동작기능 인식률도 각각 94.69, 95.63, 96.56, 96.88[%]로 증가하였으나 인식률의 증가폭은 상대적으로 적으며 가중 켑스트럼 거리 측정법의 경우에는 각각 91.88, 95, 99.69, 96.63[%]의 인식률을 보였다.

Keywords