Abstract

The effect of air gap between specimen and jig on the material constant (permittivity, permeability) and attenuation characteristics of electromagnetic wave absorbers in the coaxial line method was investigated. The presence of a air gap made both permittivity and permeability measured lower than true value, and the tendency was greater in the case of permittivity. An inner gap compared to an outer gop was found to yield a larger difference between measured and true values. The effect of air gap was measured for a Ni0.3Zn0.7Fe2O4, with the gap eliminated by metallizing with Ag-paste. The measured characteristics were in good agreement with corrected values by calculation.