According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

키워드