DOI QR코드

DOI QR Code

Heat Transfer on a Heated Flat Plate by an Impinging Round Jet Using Liquid Crystal

Liquid Crystal을 이용한 원형충돌분류의 전열특성 연구

  • Published : 1992.08.01

Abstract

Local heat transfer characteristics for a round air jet impinging normally on a heated flat plate were experimentally investigated. The problem parameters investigated were jet Reynolds number, Re=4000,10000, and 20000, and nozzle-to-plate spacing(L/D) of 2,6, and 10. The temperature variations on the flat uniform heat flux surface were mapped using a thermo-sensitive liquid crytal sheet. The isochromatic images corresponding to the characteristic temperature of liquid crystal were analyzed with the help of a digital image processing system. The local Nusselt number, Nu decreased rapidly in the impingement region and exhibited a similar profiles in the wall jet region independent of the nozzle-to-plate spacing L/D. In the case of large Reynolds number, heat transfer rate (Nu) was proportional to 0.5 power of the Reynolds number. For L/D=2, a secondary peak in the heat transfer rate was seen in the region of X/D=1.5~3 due to the transition from laminar to turbulent boundary layer.

본 연구에서는 원형수직 충돌분류에 의한 가열평판의 전열특성을 해석하기 위 하여 최근 표면온도 측정에 많이 사용되고 있는 liquid crystal을 이용하였다. 즉 liquid crystal의 감온특성과 영상처리 기법을 이용하여 레이놀즈수 및 노즐과 충돌판 사이의 거리(L/D) 변화에 따른 전열면의 온도장 변화를 측정하였다.

Keywords