Fluid Dynamics near end-to-end Anastomoses Part III in Vitro wall Shear Stress Measurement

  • Kim, Y.H. (Cardiovascular Fluid Dynamics Laboratory School of Chemical Engineering Georgia Institute of Technology)
  • Published : 1992.09.01

Abstract

The wall shear stress in the vicinity of end-to end anastomoses under steady flow condi- tions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experi- mental measurements were in good agreement lith numerical results except In flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compli- ance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia (ANFH) in end-to-end anastomoses.

Keywords

References

  1. Surg v.86 Intimal Hyperplasia as a Complication of the Use of the Polytetrafluoroethylene Grafts for FemoroPopliteal Bypass Echave,U.;Koornick,A.R.;Haimous,M.;Jacobson,J.H.
  2. Arch, Surg v.114 Boundary layer separation in models of side-to-end arterial anastomoses LoGerfo,F.W.;Soncrant,T.;Teel,T.;Dewey,C.F.
  3. J. Vasc. Surg. v.5 The Effect of Endothelial Injury on a Smooth Muscle Cell Proliferation Mason R.A.;Kui,J.K.;Campbell,R.;Giron,R.
  4. J. Cardiovasc. Surg v.21 Compliance ; A continuing problem with vascular grafts Kinley,C.E.;Marble,A.E.
  5. J. Vasc. Surg v.5 Effect of Compliance Mismatch on Vascular Graft Patency Abbott,W.M.;Megerman,Hasson,J.E.;L'Italien,G.;Warnock,D.F.
  6. Circulation v.58 Low Compliance and Arterial Graft Occlusion Kidson,I.G.;Abbott,W.M.
  7. submitted to Biorheology Steady Flow Analysis in the Vicinity of End-to-end Anastomosis Kim,Y.H.;Chamdran,K.B.
  8. Circ. Res. v.23 Application of Heated-Film Velocity and Shear Probes to Hemodynamic Studies Ling,S.C.;Atabek,H.B.;Fry,D.L.;Patel,D.J.;Janicki,J.S.
  9. Chemical Engineering Communications v.7 Wall Shear Stress in the Aorta Miller,G.E.;Hollis,T.M.
  10. Cardiovase. Res. v.3 Flow in Branching Vessels Brech,R.;Bellhouse,B.J.
  11. J. Biomechanical Eng v.108 Flush-Mounted Hot-Film Anemometer Accuracy in Pulsatile Flow Nandy,S.;Tarbell,J.M.
  12. Ph. D. Dissertation, University of Iowa Flow Dynamics in the Vicinity of an End-to-End Anastomosis and Its Relationship with Anatomotic Neointimal Fibrous Hyperplasia Kim,Y.H.
  13. draft of book Measurement of Wall Shear Stress Hanratty,T.J.;Campbell,J.A.
  14. The Fluid Mechanics of Large Blood Vessels Pedley,T.J.