An Analytical Study on the Anchorage Design in Exterior R/C Beam-Column Connections

R/C조 외측 보-기둥 접합부의 정착설계에 대한 해석적 연구

  • 최기봉 (경원대학교 토목공학과)
  • Published : 1992.12.01

Abstract

An analytical model was developed for predicting the pullout behavior of straight beam longitudinal bars anchored at exterior beam-column connections. The model incorporates a local bond constitutive simulation capable of considering the effects of anchored bar diameter, yield strength and the spacing, concrete compressive strength, and column pressure on the bond characteristics of deformed bars in confined conditions of exterior joints. The analytical techniques adopted in this study were shown to satisfactorily predict the results of pullout tests on straight bars embedded in confined concrete specimens. An evaluation of the ACI-ASCE Committee 352 development length requirements in exterior joint conditions was made using the developed analytical approach. The results of this analytical evaluation are indicative of the conservatism of the current development length requirements in the confined conditions of exterior joints.

외측 보-기둥 접합부에 정착된 곧은 보 주철근의 인발거동을 예견하기 위한 해석모델이 개발되었다. 이 모델은 외측조인트에 수직방향으로 콘크리트를 구속하기 위하여 횡방향 철근을 배치한 상태의 구속조건(confined condition)하에서 이형철근의 부착특성에 관한 정착철근의 직경, 콘크리트 압축강도, 항복강도, 철근간격 및 주압력(column pressure)에 대한 영향을 고려할 수 있는 국부부착에 관한 시뮬레이션을 구체화하였다. 이 연구에서 채택된 해석 기법은 횡방향 철근이 배근된 공시체에 매입한 곧은 이형철근에 대한 인발실험의 결과를 만족하게 예견하였다. ACI-ASCE 352 위원회가 제안하고 있는 외측조인트 상태에서의 정착 철근길이에 관한 규정이 개발된 해석접근법을 사용해 평가 되었다. 이 해석 평가의 결과는 현재의 외측조인트의 구속조건에서의 정착길이에 대한 규정이 너무 안정적인 측면에 있다는 것을 암시하고 있다.

Keywords