Maximum Torque Operation of an Induction Machine in the field weakening regoin

약계자 영역에서 유도전동기의 최대 토오크 운전

  • Published : 1994.02.01

Abstract

In this paper, a new approach for the induction machine control whih ensures producing maximum torque per ampere over the entire field weakening region is presented. In addition, the relation of the output torque capability with the leakage factor of the machine is examined. Also the smooth and precise transition into the field weakening operation can be achieved by adjusting the base speed for the field weakening operation according to the flux level, the current limit and the voltage limit. The proposed is verified through simulation and experiment for a 5hp laboratory induction motor drive system.