RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System

SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석

  • Published : 1994.06.01

Abstract

The sudden discharge of the loop seal water, which is present upstream of the SEBIM POSRV, creates large momentum and inertia forces on the downstream of the discharge piping system. This study provides the procedures and results of analysis of the thermal-hydraulic transient in the SEBIM POSRV discharge piping during the valve opening. The analysis is peformed by RELAP5/MOD3. The appropriate modeling of the discharge piping system, SEBIM POSRV opening characteristics, and loop seal water discharge for the RELAP5/MOD3 analysis is suggested. Also performed is the sensitivity study for the selection of proper options for the junction and volume control. flags. The analysis results demonstrate the adequacy of the RELAP5/HOD3 for the thermal-hydraulic transient analysis of the loop seal water discharge of the SEBIM POSRV discharge piping system. From the sensitivity analysis results, it is shown that the smooth area change option with reasonable geometric pressure drop distribution, non-equilibrium option, and proper time step should be selected for loop seal water discharge analysis.

SEBIM 밸브 상부에 위치한 밀봉수의 급격한 방출은 밸브 후단의 방출배관계통에 큰 운동량과 관성력의 작용을 초래한다. 본 연구는 밸브개방시 방출배관계통의 후단에 발생하는 열수력학적 과도현상을 분석하기 위한 해석절차 및 해석결과를 다루고 있으며, 이 분석을 위해 RELAP5 /MOD3 를 사용하였다. RELAP5 /MOD3 분석을 위하여, 방출관 계통과 SEBIM 밸브의 개방특성 및 밀봉수 방출등의 적절한 모델방법이 제시되었다. 또한 접합부(junction)와 체적(volume)의 제어 플래그 (flag)에서 옵션(option)의 적절한 선택을 위하여 민감도분석도 수행되었다. 분석결과, SEBIM 밸브 방출배관계통의 밀봉수 방출에 따른 열수력학적 과도현상을 분석하는데 RELAP5 /MOD3가 적절히 사용될 수 있음을 알 수 있었다. 민감도 분석결과로부터, 밀봉수 방출해석을 위해서는 적절한 기하학적 압력분포를 가지는 완만한(smooth) 면적변화 및 비평형 옵션(option), 적절한 시간간격(time step)의 사용이 필수적인 것을 알 수 있었다.

Keywords