X선촬영실 내에서의 공간산란선량 변동에 관한 연구

A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room

  • 오현주 (신구전문대학 방사선과) ;
  • 김성수 (신구전문대학 방사선과) ;
  • 김영일 (신구전문대학 방사선과) ;
  • 임한영 (인산전문대학 방사선과) ;
  • 김흥태 (신흥전문대학 방사선과) ;
  • 이후민 (동남보건전문대학 방사선과) ;
  • 김학성 (동남보건전문대학 방사선과) ;
  • 이상석 (동남보건전문대학 방사선과)
  • Oh, Hyun-Joo (Dept. of Radiotechnology, Sin Gu College) ;
  • Kim, Sung-Soo (Dept. of Radiotechnology, Sin Gu College) ;
  • Kim, Young-Il (Dept. of Radiotechnology, Sin Gu College) ;
  • Lim, Han-Young (Dept. of Radiotechnology, In San Junior College) ;
  • Kim, Heung-Tae (Dept. of Radiotechnology, Shin Heung Junior College) ;
  • Lee, Who-Min (Dept. of Radiotechnology, Dong Nam Junior Health College) ;
  • Kim, Hak-Sung (Dept. of Radiotechnology, Dong Nam Junior Health College) ;
  • Lee, Sang-Suk (Dept. of Radiotechnology, Dong Nam Junior Health College)
  • 발행 : 1994.12.15

초록

In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

키워드