다이아프램이 없는 콘크리트 충전 원형강관 기둥-H형강 보 접합부의 구조적 거동에 관한 실험적 연구

Experimental Study on the Structural Behavior of Concrete-Filled Circular Tubular Column to H-Beam connections without Diaphragm

  • 강현식 (한양대학교 건축공학과) ;
  • 문태섭 (한양대학교 건축공학과, 포항제철(주))
  • 발행 : 1997.03.30

초록

This paper is concerned with an experimental study on structural behavior of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections. The important parameters are the number of inner reinforced rib and the width of H-beam flange(100, 150, 200mm) with variable column thickness(5.8mm, 9.2mm, 12.5mm) around the joint between CFCT and H-beam. Test results are summarized for the displacement, strength, initial stiffness, failure mode and energy absorption capacity of each specimen. The purpose of this paper is to investigate the initial stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections. From the discussion about the test results, the basic data for non diaphragm connection design would be suggested.

키워드

참고문헌

  1. 대한건축학회학술발표논문집 각형 강관 접합부의 보 형상에 따른 강성 및 내력 성낙봉;신경재;오영석;이명재;문태섭
  2. 鋼構造塑性設計指針 日本建築學會
  3. 鋼構造接合部の力學特性に關する硏究の現況 日本建築學會
  4. Connections in Steel Structures II AISC
  5. Journal of Structural Engineering v.116 no.11 Classification System for Beam-To-Column Connections Bjorhovde