Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA)

Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교

  • Published : 1997.12.01

Abstract

Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

목적: 자기공명혈관조영술(magnetic resonance angiography: MRA)을 이용하여 뇌동맥류를 비침습적 방법으로 진단하고자 하는 시도가 있었지만 크기가 3mm 이하인 경우 진단에 애로가 많았다. 뇌동맥류의 진단에 있어 최근 개발된 고해상도, 고속의 slice interpolation 자기 공명혈관조영술과 디지탈 감산 혈관조영술(digital subtraction angiography: DSA)의 결과를 전향적으로 비교하여 보편적인 선별 검사법으로 가능성을 확인하고자 하였다. 대상 및 방법: 총 19명의 환자에서 26개의 뇌동맥류를 대상으로 하였다. 모두 자기공명혈관조영술을 먼저 촬영하여 기원혈관, 동맥류경부의 확인, 인근 작은 혈관과의 연관관계등을 확인한 후 디지탈 감산 혈관조영술을 시행하여 비교하였다. 영상은 1.5T 초전도형기계(Vision, Siemens, erlangen, Germany)를 이용하여 slice interpolation 을 이용한 자기공명혈관조영술로 촬영하였다. 촬영은 TR / TE / FA = 30 / 6.4 / 25, matrix $512{\times}160$, 관찰면 $200{\times}150$, 촬영시간 7분 42초, 유효 두께 0.7mm, 총 두께가 102.2mm로 하여 대공(foramen magnum)에서 전뇌동맥(anterior cerebral artery)의 A3 부위까지 충분히 포함되도록 하였다. 영상분석은 최대강도투사(maximum intensity projection: MIP)를 사용하였으며 두개강내 동맥류가 있는 경우 다면재구성(multiplanar reconstruction: MPR) 기법을 사용하였다. 결과: 19명의 환자중 2명이 3개, 3명이 2개, 나머지 14명이 각각 1개씩의 두개강내 동맥류를 가져 모두 26개 였으며 파열된 동맥류가 14개였고 파열되지 않은 동맥류가 12 개이었다. 크기가 2mm 이하가 8개, 3-5mm가 9개, 6-9mm가 7개이며 10mm이상이 2개가 있었다. 처음 검사에서 자기공명혈관조영술과 디지탈 감산 혈관조영술에서 23개의 동맥류중 내경동맥에 1mm 크기의 동맥류 1개를 제외한 25개를 각각 발견할 수 있어 96%의 예민도를 보였으나 진음성과 위음성은 없어 특이도를 측정할 수 없었다. 크기와 모양을 확인하는데 자기공명혈과조영술과 다면재구성을 동시에 사용한 경우 디지탈 감산 혈관조영술과 같은 성적을 보인 반면 동맥류 경부와 기원혈관을 확인하는데도 자기공명혈관조영술의 다면재구성을 동시에 사용한 경우가 자기공명혈관조영술 또는 디지탈 감산 혈관조영술만 사용한 경우 보다 월등히 좋았다. 결론: Slice interpolation 기법을 이용한 고해상 자기공명혈관조영술은 두개강내 동맥류를 검사하는데 디지탈 감산 혈관조영술과 동일한 성적을 보여 앞으로 비침습적 일차 선별 검사법으로 가능할 것으로 생각된다.

Keywords