A Pilot Study for Introducing Advanced Water Treatment Facilities at Nakdong River

낙동강수계 고도정수시설 도입을 위한 PILOT 실험 연구

  • 오세원 (코오롱엔지니어링(주) 환경기술연구소) ;
  • 최광호 (코오롱엔지니어링(주) 환경기술연구소) ;
  • 최수일 (코오롱엔지니어링(주) 환경기술연구소) ;
  • 손성섭 (코오롱엔지니어링(주) 환경기술연구소)
  • Published : 1997.01.15

Abstract

To obtain design and operating parameters for advanced water facilities, pilot test consisted of ozonation and GAC filtration was conducted at midstream of Nakdong River. Even though the concentrations were very low, 62 chemicals were detected above $0.005{\mu}g/L$ in raw water. In the preozonation, natural organic matters which could produce THMs and organics such as phenols and amines were effectively removed. The performance of TOC removal of GAC filtration with ozonation was better than GAC filtration alone and adsorption capacity of GAC adsorbers were ranged 3~6mg-TOC/g-carbon. And also the life of GAC adsorber for removing TOC was predicted more than 1 years if ozonation is introduced. This indicates that biological degradation of organics happened in GAC filters. Most organics detected at ppt level were removed below detection limit by GAC filtration with ozonation. These results show that ozonation and GAC filtration are the reliable and safe process for organic contaminants and chlorinated byproducts control at Nakdong River.

Keywords