DOI QR코드

DOI QR Code

An experimental study on the dynamic characteristics of a residential air-conditioner with a R22 alternative refrigerant

R22 대체냉매 에어컨의 동적 특성에 대한 실험적 연구

  • 김만회 (삼성전자 기술총괄 생활시스템연구소)
  • Published : 1998.03.01

Abstract

This study presents experimental results on the shut-down and start-up characteristics of a residential split-system air-conditioner with capillary tube, using R410A as a R22 alternative refrigerant. During shut-down, the transient characteristics are evaluated by measuring the high side and low side pressures and temperatures of the system. The dynamic behavior of the system after start-up is also investigated at the high temperature cooling test condition. All experiments are performed in psychrometric calorimeter. The cooling capacity, power consumption, dehumidification capacity and cycle characteristics after start-up are analyzed.

Keywords

References

  1. Ph. D. Thesis, Purdue University Transient Analysis of Refrigerating System Dhar, M.
  2. ASHRAE Trans. v.85 The Degradation Coefficient of a Field Tested Self-Contained 3-Ton Air-Conditioner Murphy, W. E.;Goldschmidt, V. W.
  3. ASHRAE Trans v.86 A Note on the Transient Performance and Degradation Coefficient of a Field Tested Heat Pump-Cooling Mode Goldschmidt, V. W.;Hart, G. H.;Reiner, R. C.
  4. Int. J. pf Refrig. v.5 no.3 A Simulation of Trasiert Performance of Heat Pump Chi, J.;Didion, D. A.
  5. ASHRAE Trans. v.88 Experimental Study on the Dynamic Characteristics of a Heat Pump Tanaka, N.;Ikekuchi, M.;Yamanaka, G.
  6. ASHRAE Trans. v.90 Transient Response of Air-Conditioners-a Qualitative Interpretation Through a Sample Case Murphy, W. E.;Goldschmidt, V. W.
  7. ASHRAE Trans. v.91 Refrigerant Migration in a Split-Unit Air-Conditioner Mulroy, W. J.;Didion, D. A.
  8. ASHRAE Trans. v.91 Cyclic Characteristics of a Residential Air-Conditioner-Modeling of Start-up Transient Murphy, W. E.;Goldschmidt, V. W.
  9. ASHRAE Trans. v.92 Cyclic Characteristics of a Residential Air-Conditioner-Modeling of Shutdown Transient Murphy, W. E.;Goldschmidt, V. W.
  10. Int. J. of Refrig. v.11 Transient Mass Flow Rate of a Residential Air-to-Air Heat Pump Belth, M. L.;Grzymala, T. E.;Tree, D. R.
  11. Ph. D. Thesis, Texas A&M University A Study of the Transient Behavior During Start-Up of Residential Heat Pumps Katipamula S.
  12. Int. J. of Refrig. v.13 Start-Up and Shut-Down Operation in a Reciprocating Compressor Refrigeration System with Capillary Tubes Wang, J.;Wu, Y.
  13. 고려대학교 박사학위논문 소형냉동시스템의 시동시 동적 성능에 관한 시뮬레이션 및 실험적 연구 한창섭
  14. Ph. D. Thesis, The Technical University of Denmark Energy Optimization of Refrigeration Systems: The Domestic Refrigerator-a Case Study Jakobsen, A.
  15. Int. J. of Refrig. v.18 no.3 Factors Contributing to Refrigerator Cycling Losses Rubas, P. J.;Bullard, C. W.
  16. ASME, AES v.34 The Transient and Steady State Performance of R-22 and R-407C, Heat Pump and Refrigeration Systems Design, Analysis and Applications Judge, J. F.;Radermacher, R.
  17. NIST Thermodynamic Properties of Refrigerants and Refrigerant Mixtures Database(REFPROP), Version 5.0 Huber, M.;Gallagher, J.;McLinden, M.;Morrison, G.