Abstract

The accurate measurement of the room sound level is required in environment noise control. However, it has been found that the measurement system noise always corrupts the actual noise from the sound source. In this study, a new sound level measurement technique in which the system noise is eliminated from the measured signal by the cross spectrum method, is proposed. The received signals of two measuring microphones are recorded to DAT through the pre-amplifier and digitized by A/D converter. The cross spectrum calculated from the digitized signals gives the accurate sound level since the system noise is uncorrelated with the sound source noise which we want to measure. The performance of the proposed technique is verified experimentally to be effective and the technique is found to be economic since the low cost general purpose microphone could be used in this technique.

실내 소음의 정확한 측정은 환경소음 관리상에 요구되어 지는 것이나 측정계 자체의 잡음으로 인하여 소음원이 가지는 원래의 잡음이 항상 영향을 받게되는 문제가 있다. 본 연구에서는 새로운 소음레벨 측정기술로서 크로스 스펙트럼법을 사용하여 측정된 신호로부터 측정계가 가지는 잡음을 효과적으로 제거하는 방법을 제안하였다. 두 개의 측정용 마이크로폰으로부터 받아들인 신호는 각각의 전치 증폭기를 통하여 A/D 변환기에 의해 디지털 신호화하여 크로스 스펙트럼을 이 디지털화 된 신호로부터 계산하고 측정계가 가지는 잡음과 소음 원의 잡음은 서로 무상관이므로 우리가 원하는 정확한 소음레벨을 측정할 수 있는 것이다. 제안된 기술의 성과는 염가의 상용 마이크로폰으로도 사용할 수 있었기 때문에 실험적으로 그 유효성과 경제성이 입증되었다.

Keywords