환경위생공학 (Journal of environmental and Sanitary engineering)
- 제14권4호
- /
- Pages.41-49
- /
- 1999
- /
- 2005-5889(pISSN)
다단오존접촉조에서 유해화학물질의 제거특성
Removal Characteristics of Hazard Organic Substances in the Multi-stage Ozone Contactor
초록
The water treatment by was performed to remove VOC and organic substances in the multi-stage ozone contactor. Ozone is mainly utilized to change the chemical structures of organic substance, of which finally has the purpose to degrad them. The removal efficiency of VOC has 20~60% at the ozone concentration of 3 ppm, in case of trichloroethylene, its efficiency is reduced by 85% at the ozone contact time of 8 min. Design factors such as the number of stage, ozone concentration, zone contact time are determined for optimal treatment in the multi-stage contactor.