가시광선 및 근적외선 스펙트럼을 이용한 도정비율 측정

Measurement of Milling Ratio using the Visible and the Near-Infrared Rays Spectrum

  • 이용국 (성균관대학교 생물기전공학과 정회원) ;
  • 이재현 (성균관대학교 생물기전공학과 학생회원)
  • 발행 : 1999.06.01

초록

This research was carried out to investigate the possibility of real time rice milling ratio measurement using the spectral reflection characteristics. In this study, various methods were compared such as \circled1 using the whiteness meter, \circled2 using the colorimeter, \circled3 using the Visible and the NIR reflection spectrum. The samples were milled in the domain of 84~96% by 0.5% interval classified by milling ratio. The NMG treatment method required about 20 minutes to determine the milled ratio and r2 was 0.0028 to 0.7959 that was very low. In case of whiteness meter, r2 was high but speed of measurement was 5 minutes that was very low. Measurement with the colorimeter required about 5 minutes and r2 was 0.60 to 0.85 that was low. The reflection spectrum were measured in the range of 400~2,500nm with 2nm interval and the MLR model with six-wavelength obtained from first derivative of spectra gave the best results(r2 = 0.967, SEP = 0.729%)

키워드