초록

Current design code states that the strength reduction factor shall be permitted to be increased linearly from that for axial compression to that for flexure as the design axial load strength $\Phi$cPn decrease from 0.1fckAg to zero. Since this empirically adopted axial load level of $\Phi$cPn=0.1fckAg considers only sectional area and concrete strength, the other variables such as steel ratio, steel yielding strength, and steel arrangement can not be considered. This research is performed to investigate the consistency and the rationality of the code requirement for determination of column design strength. A nonlinear axial force-moment-curvature analysis was conducted in order to investigate the ductility of reinforced concrete column sections. As the result of ductility analysis, it was found that the ductility at the axial force of $\Phi$cPn=0.1fckAg represented a lock of consistency for the various variable contained sections. Therefore, a more reasonable application method of strength reduction factor is proposed, that is based on the strain ductility index.

키워드

참고문헌

  1. 콘크리트표준시방서 대한토목학회
  2. 콘크리트구조설계기준 한국콘크리트학회
  3. American Concrete Institute Building Code Requirements for Structural Concrete and Commentary ACI Committee 318.
  4. ACI Structural Journal v.89 no.2 Unified Design Provisions for Reinforced and Prestressed Concrete Flexural and Compression Memvers Mast, R. F.
  5. Concrete International φ-Factors and Other Anomalies William L. Gamble
  6. Concrete International ACI 318-95 Appendix B : Beam Design Applications Furlong, R. W.
  7. Reinforced Concrete Structures R. Park;T. Paulay
  8. 대한토목학회논문집 v.4 no.3 철근콘크리트 휨부재의 연성지수에 관한 해석적 연구 이재훈
  9. Concrete International v.15 no.5 Structural Design Consideration for High-Strength Concrete Collins, M.P.;Mitchell, D.;MacGregor, J. G.