Frequency control method of ozonator power supply

오존발생기 구동장치의 주파수제어에 관한 연구

  • 최규남 (인천전문대학 공학부 통신과)
  • Published : 1999.12.01

Abstract

The characteristics of ozone generator targeted for air or water sterilizing in the vessel utilizing the surface corona discharge between the electrodes on the ceramic substrate was investigated by using the frequency control method. The frequency control was achieved by controlling the degree of resonance between the secondary winding inductance of transformer and the electrode capacitance of ceramic discharge plate, and the range of control was found to be 5 times of discharge current. This frequency control method showed the efficiency of 28 mP ozone generation and the stability within 3.4 % when the input voltage was varied within 40% range. The frequency control method is regarded to be more efficient way of corona discharge control compared to the conventional on/off control or voltage control methods.

선박 내 공기정화나 음료수 살균용으로 제작된 세라믹 방전판 상하면에 패턴된 전극간에 일어나는 연면 코로나 방전을 이용한 오존발생기 구동장치의 주파수제어 특성에 대하여 분석하였다. 고압변압기의 2차측 권선 자체의 인덕턴스와 세라믹 방전판 전극 자체의 용량간의 공진도를 주파수제어를 통하여 제어하여 최고 5배의 전류제어범위를 실현하였다. 기존의 전압제어 및 단속제어방식에 비하여 주파수제어 방식은 28 mg/W의 오존발생 효율과 40% 의 입력전압 변동에 대하여 3.4 % 이내의 방전전류 안정도를 갖는 것으로 측정되었다.

Keywords