Mechanical Behaviors of Studs and High-Tensile Bolts by Push-Out Test

Push-Out Test에 의한 스터드와 고장력 볼트의 역학적 거동

  • Received : 1999.03.05
  • Published : 1999.04.30

Abstract

Shear connectors are completely important to composite each other in steel concrete composite structures. Therefore a strength of shear connectors and relation of a load-slip have been carried out experimentally and analytically by the Push-Out test for this study. In this paper, eleven specimens were tested and the behavior of shear connectors in steel concrete composite structures are investigated.

Keywords