An Experimental Study on the Elasto-Plastic Behavior of High Strength Column to Beam Welded Connection

고강도강 기둥(SM570) 보 용접접합부의 탄소성거동에 관한 실험적 연구 -스캘럽상세와 패널강성을 중심으로-

  • Received : 2000.08.07
  • Published : 2000.10.27

Abstract

This paper intends to propose design information with the result or comparing the deformation capacity with different panel stiffness specimens and estimating the plastic deformation capacity, toughness and strength of welded joint connection according to the different scallop types. The test results of the beam to column unit structure are as follow: the non-scalloped and the low stiffness panel specimen have more desirable result values than the scalloped and the high stiffness one in plastic deformation. Comparing the scallop types shows very unlikely tendency as follows, second cracking occurs at the very edge of scallop in the scalloped specimen otherwise cracking occurs bond area of welded beam flange in the non-scalloped one.

고강도강 기둥-보 접합부는 용접방법에 따라 응력집중 및 균열의 발생진전에 큰 차이가 있다. 그러므로 공장제작형 디테일에 대한 내력과 인성, 용접접합부의 소성변형 능력과 패널의 강성에 의한 변형능력의 차이 등을 비교 검토하여 설계자료로 제시하고자 한다. 실험결과는 다음과 같다. 첫째, 누적소성율과 소성변형배율, 내력상승을 모두 논스캘럽이 스캘럽 시험체 보다, 약패널이 강패널 보다 우수한 것으로 나타났다. 둘째, 시험체의 2차균열 발생은 스캘럽 단부에서 발생하였으나, 논스캘럽 시험체는 보플렌지 용접 본드부에서 발생하여 집합부 상세에 따라 상이한 경향을 나타내었다.

Keywords

References

  1. 대한건축학회 논문집 고강도강 기둥(SM520. 570)과 보 용접접합부의 탄소성거동에 관한 연구 김종락;김성배
  2. 鋼構造限界狀態構造設計規準.同解說 日本建築學會
  3. 高性能鋼利用技術指針
  4. 構造工學論文集 v.39B はり端溶接接合部のカ學的擧動におよぽすスカラップの影響 山本昇;石井匠;森田耕次
  5. 構造工學論文集 v.39B 高性能鋼HT590を用いた柱梁溶接接合部におけるH形鋼梁端部のカ學的性能 矢部喜堂;坂本眞一
  6. 日本建築學會構造系論文報告集第 no.449 590N/mm2級高性能鋼を用いた柱梁溶接接合部のカ學的性能に關する實驗的硏究 中?忠男;山田丈富;市川祐一;坂本眞一;李建;中野秀二
  7. 日本建築學會論文報告集 no.309 鋼構造柱はり接合部にお ける柱フランジの板厚方向歪度とその分布に關する實驗 藤本盛久;松下眞治