Evaluation of Structural Integrity for HANARO Capsule Structure by Vibration Test and Analysis

진동시험 및 해석을 통한 하나로 캡슐 구조물의 구조건전성 평가

  • Published : 2000.04.01

Abstract

The instrumented capsule is subjected to flow-induced vibration(FIV) due to the flow of the primary coolant and then the structural integrity of the capsule during irradiation in the HANARO reactor is an issue of major concern. For this purpose the acceleration was measured by four accelerometers attached to the protection tube of the capsule mainbody and the displacement of test holes was calcultated using commercial finite element program ANSYS to evaluate the structural interference with the neighboring flow tubes under the reactor operating condition. The calculated displacements of test holes in the reactor in-core were found to be lower than the values of allowable design criteria.

Keywords

References

  1. KAERI/RR-1398/93 KMRR을 이용한 노내검증실험평가기술개발 강영환 외
  2. Flow-Induced Vibration Blevins,R.B.
  3. Flow-Induced Vibration of Circular Cylindrical Strctures Chen,S.S.
  4. KAERI/RR-1510/94 노내시험시설 설계건조(부록2) 강영환 외
  5. HAN-IC-DD-PR-01 97M-01K 캡슐 하나로 조사시험전 진동시험 절차서 한국원자력연구소
  6. ANSYS Engineering Analysis System User's Manual for Revision 5.3 Swanson Analysis System,Inc.
  7. HANTAP-09-RT-002(Rev.1) 특수시험시설절차서 .하나로 조사시험연료 진동시험절차서 한국원자력연구소
  8. KAERI/TR-985/98 재료조사시험용 캡슐 및 관력 설비의 안전성 분석보고서 한국원자력연구소
  9. 한국원자력학회'96추계학술대회 논문집(Ⅱ) 하나로 캡슐 지지용 와이어 스프링의 강성해석 강영환;이영신;최명환
  10. Master Series Manual Lawry,M.H.
  11. Formulas for Natural Frequency and Mode Shape Blevins,R.B.