Separation Performance of Disc Plate and Frame Type Reverse Osmosis System

원판틀형 역삼투 시스템의 투과성능

  • 노상호 (한양대학교 화학공학과) ;
  • 이종일 (한양대학교 화학공학과) ;
  • 김영채 (한양대학교 화학공학과) ;
  • 배성렬 (한양대학교 화학공학과) ;
  • 정건용 (서울산업대학교 화학공학과)
  • Published : 2000.09.01

Abstract

The reverse osmosis membrane housing(HY) was developed for excellent distribution of a feed solution, and the separation performance was compared with the commercialized Rochem(RC) system. The permeation flux of HY system was a little lower than that of RC system. On the other hand, the NaCl rejection ra4io was generally higher. Also, the permeation flux and rejection ratio for type A, B and C modules(disc plate and frame type) were measured using NaCl, sucrose and butanol solutions. The separation performance of type C module for NaCL and sucrose solutions was the most effective, and then those of type A and B were followed, respectively. However, the separation performance for butanol solution was type B, C and A order. The flux improvement ratio of type B to A increased as butanol concentration decreased or operating pressure increased up to 28 bar.

공급수가 원판틀형 모듈에 잘 분포될 수 있는 역삼투형 하우징(HY)을 개발하여 설계 제작하였으며 상용화된 Rochem(RC)시스템과 투과성능을 비교하였다. 자체 개발한 HY시스템은 RC시스템에 비하여 투과유속이 약간 떨어지는 반면, NaCl 배제율은 전반적으로 높았다 원판틀형 모듈인 type A, B, C에 대한 투과유속 및 배제율을 NaCl, sucrose 및 butanol 수용액으로 측정하였다. NaCl 및 sucrose의 경우, type C, A, B의 순으로 투과성능이 우수하였으나 butanol의 경우는 type B, C, A 순이었다. Type A에 대한 type C의 butanol 투과유속은 농도가 감소할수록 그리고 28 bar 범위내에서 운전압력이 증가할수록 향상되었다.

Keywords

References

  1. J. Membrane Sci. v.80 H.B.Winzeler;G.Belfort
  2. Membranes in Bioprocessing J.A.Howell;V.Sanchez;R.W.fileld
  3. J. Membrane Sci. v.81 K.Y.Chung;R.Bates;G.Belfort
  4. Chem. Eng. Comm. v.153 K.Y.Chung;E.J.Kim
  5. 멤브레인 v.7 no.2 박민수;배성렬;정건용
  6. The 4th Japan-Korea Symposium on Separation Technology S.C.Yi;S.Y.Bae;J.M.Won;B.H.Ha
  7. Reverse Osmosis S.Sourirajan