ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES

가시광선영역에서 shade guide에 따른 광투과도 특성 연구

  • Choi, Keun-Bae (Department of Prosthodontics and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University) ;
  • Park, Charn-Woon (Department of Prosthodontics and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University) ;
  • Song, Chang-Yong (Department of Prosthodontics and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University) ;
  • Ko, Sok-Min (Department of Prosthodontics and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University)
  • 최근배 (전북대학교 치과대학 보철학교실 및 구강생체과학연구소) ;
  • 박찬운 (전북대학교 치과대학 보철학교실 및 구강생체과학연구소) ;
  • 송창용 (전북대학교 치과대학 보철학교실 및 구강생체과학연구소) ;
  • 고석민 (전북대학교 치과대학 보철학교실 및 구강생체과학연구소)
  • Published : 2000.04.01

Abstract

The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

Keywords