Performance Analysis of the Centrifugal Pump Impeller Using Commercial CFD Code

상용 CFD코드를 이용한 원심펌프 임펠러의 성능해석

  • 최영석 (한국생산기술연구원 냉동공조연구팀) ;
  • 이용갑 (한국생산기술연구원 냉동공조연구팀) ;
  • 홍순삼 (서울대학교 대학원) ;
  • 강신형 (서울대학교 기계항공공학부)
  • Published : 2001.03.01

Abstract

A commercial CFD code is used to compute the 3-D viscous flow field within the impeller of a centrifugal pump. Several preliminary numerical calculations are carried out to determine the influence of the parameters such as the grid systems, the numerical schemes, the turbulence models and the shape of the vaneless diffusers at the design flow rate. The results of the preliminary study are used for the calculation of the off-design flow conditions. The circumferentially averaged results such as the radial and tangential velocities, the exit flow angle, the slip factor, the static pressure and the total pressure are compared with the experimental data at the impeller exit to discuss the influence of the prescribed parameters.