Effect on the Hydrogen Peroxide in the Ozonation of Ammonia

오존에 의한 암모니아 산화시 과산화수소가 미치는 영향

  • 박문숙 (나주대학 보건위생과) ;
  • 안재동 (서강정보대학 환경공학과) ;
  • 노봉오 (조선대학교 화학교육과)
  • Published : 2001.03.01

Abstract

Ammonia is used in the manufacture of fertilizers, refrigerants, stabilizers and many household cleaning agents. These wide applications resulted in ammonia contamination in water. Ammonia can be removed from water by physical, biological, and chemical methods. Ozonation is effictive in the treatment of water with low concentration of ammonia. This study is undertaken to provide kinetic data for the ozonation of ammonia with or without hydrogen peroxide. The results were as follows; The destruction rate of ammonia increased gradually with the influent hydrogen peroxide concentration up to 0.23 mM and inhibited in the range of 0.23~11.4mM, and the maximum removal rate of ammonia achieved at 0.23mM of hydrogen peroxide, and the overall kinetics was first order. The combination effect of hydrogen and ozone to oxide ammonia in aqueous solution was better than ozone alone. The reacted ammonia was converted completely to nitrate ion.

Keywords