Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Published : 2001.10.01

Abstract

Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

Keywords

References

  1. Jacob Butel, Harold L. Kundel, 'Handbook of medical Imaging, Volume 1. Physics and Psychophysics', SPIE PRESS, p229-253 (1998)
  2. Priv. Doz. Dr, ' Evaluation of the new RadioVisioGraphiy system image quality', Oral Surg Oral Surg Med. Oral Pathol, Vol 72, P627-631, (1991)
  3. Hamamatsu, 'FOS for Digital X-ray imaging', Hamamatsu, Cat. No. TMCP9003E01, (1997)
  4. Psul P. 'CCDs Reduce Radiation Exposure at the Dentist's', Laurin Publishing Co., Inc, (1997)
  5. Istvan Nadey, Stephen Ross,'Charge-coupled-deverce/fiberoptic taper array X-ray detector for protein crystallographyl,' ,SPIE Vol.3019, (1997)
  6. Andrew D A Maidment, Martin J Yaffe, 'Analysis of singnal propagation in optically coupled detectors for digital mammography: Ⅰ. Phosphor screens', Phys. Mde. Biol. vol 40, p877, (1995)
  7. Ho Kying Kim, Gyuseong Cho, 'Monte Carlo studies of metal/phosphor screen in therapeutic X-ray imaging' Nucl. Instru. and Meth. in Phy. Res. A 422, p 71 3-717(1999) https://doi.org/10.1016/S0168-9002(98)01023-7
  8. Hans-Goran Grondahl, 'An Image Plate System for Digital Intra-oral Radiography,' Dental Radiography, (1996)
  9. A Workman and DS Brettle, 'Physical performance measure of radiographic imaging systems' Dentomaxillofacial Radiology, Vol 26, p 139-146, (1997) https://doi.org/10.1038/sj.dmfr.4600241
  10. SHANNON and WYANT, 'Fiber Optics' Applied optics and optical engineering, Vol. 4, p1-29
  11. Glenn F.Knoll, 'Radiation Detection and Measurement Third Edition', Wiley, (2000)
  12. Micheal J. Flynn, 'Quantun Noise in Digital X-ray Image Detectors Whith Optically Coupled Scintillators.', IEEE Trans.Nucl.Scie.,vol. 43, No.4 (1996)
  13. G.F.Knoll, 'Detector a Program for Modeling Optical Properies of Scintillator', TRIUMF, (1996)
  14. Robert K. Swank, 'Absorpiton and nise in x-ray phosphors.', General Electric Corporate Reaserch and Development, (1973)