Developments of nondestructive evaluation techniques for reduction of strength or toughness by aging of material have been carried out, and the method using electrical resistivity is one of them. In this study, to examine the application of electrical resistivity to the evaluation of degradation of metallic alloy, ten different non-magnetic materials were selected as test materials. Electrical resistivities measured by DC two-point probe method and those measured by non-contact type eddy current method were compared with each other. In addition, to examine the application possibility of four-point probe technology in field, the electrical resistivities for 1Cr-lMo-0.25V steel measured by DC two-point probe method and four-point probe method were compared with each other Differences between two measured values for the 1Cr-1Mo-0.25V steel were 0.6%. Therefore, the four-point probe method can be applied to the estimation of the degradation of metallic alloy. ect.

재료의 노화에 의한 강도 및 인성 감소치를 정량적으로 평가하는 비파괴적 기법의 개발이 시도되고 있으며 전기비저항법도 그 중의 하나이다. 본 연구에서는 전기비저항법의 열화도 평가에의 적용성을 살펴보기 위해 먼저 6종 10 가지의 비자성 금속을 측정시료로 선택하여 직류 two-point probe법(혹은 2탐침법)으로 전기비저항을 계산한 결과와 비접촉식 와전류 방법으로 전기비저항을 측정한 결과를 서로 비교하였다. 또한, 1Cr-1Mo-0.25V강에 대하여 비파괴적 측정 방법인 four-point probe 방법(혹은 4탐침법)을 사용하여 얻은 결과와 기존의 2탐침법을 사용하여 얻은 결과를 서로 비교하여 현장에서의 4탐침 기술의 적용 가능성을 살펴보았다. 1Cr-1Mo-0.25V강에 대하여 2탐침법으로 구한 비저항 값과 4탐침법으로 구한 비저항 측정값의 차이는 0.6%였다. 따라서 4탐침법을 사용하여 현장에서 금속소재의 열화도의 비파괴적 평가가 가능하다고 사료된다.