A study on the physico-chemical characteristics of municipal solid wastes generated in the sunchon city

순천시의 생활폐기물 발생량 예측 및 재활용시설의 용량산정에 관한 연구

  • Hu, Kwan (Dept. of Environment Sunchon first college) ;
  • Moon, Ok-Ran (Dept. of Environmental Engineering chosun Univ.) ;
  • Wang, Seung-Ho (Dept. of Environmental Engineering yosu Univ.)
  • 허관 (순천제일대학 환경과) ;
  • 문옥란 (조선대학교 환경공학과) ;
  • 왕승호 (여수대학교 환경공학과)
  • Published : 2001.12.30

Abstract

The purpose of this study is to provide basic information for a future countermeasure municipal and to establish several wastes policy after investigating solid wastes from Sunchon City. In addition, this research can be supported to manage of recycling plant and to reuse plant of each wastes. Results are as bellows after checking up and analysis type of waste in Sunchon city Unit solid waste generation rate from single family is $0.50kg/person{\cdot}day$, and total solid wastes are 41.9ton/day. Unit solid waste generation rate from apartments is $0.45kg/person{\cdot}day$, and solid wastes generation is 55.5ton/day. Unit solid waste generation rate from agricultural is $0.22kg/person{\cdot}day$ and total solid wastes are 13.5ton/day. That show total amount of municipal solid wastes from residential are 110.9ton/day. Unit solid waste generation rate from traditional markets is $1.85kg/person{\cdot}day$, and solid waste total volume is 5,400kg/day. Unit solid waste generation rate from small store is $2.03kg/person{\cdot}day$, and solid waste total are 25,101kg/day. Therefore, this show that total wastes are 30.50kg from downtown and commercial area. Solid waste quantity from Industrial area (Factory region) is 8.5ton and in case of school and hospitals are 7.2kg/day and 3.0kg/day. Solid waste amount from Institutional is 6.6kg/day. Food wastes were eliminated from municipal solid wastes as standard 63.4ton/day, and combustible wastes were 126.9ton/day. If it schedule about 5 years (by 2006) as durable year for food wastes treatment plant, it is expected 42.5ton/day for treatment capacity. We can judge that it is effective to be set 2 lines equipment ${\times}25ton/day$ as treatment ability under considering unexpected working condition such as any repair, trouble and an electrical load. If it schedule about 10 years (by 2011) as durable year for food wastes treatment plant, it is expected 150 ton/day for treatment capacity. We can conclude that it is effective to be set 2 lines equipment ${\times}80ton/day$ as treatment ability under considering working condition such as low loaded operating and the repair for incineration.

순천시 생활계폐기물의 배출특성을 제시하고 장래 폐기물대책을 수립하는 기본적인 자료로 정보를 제공하고자 폐기물별 자원화시설의 용량을 산정하고 재활용시설의 운영관리 및 제반폐기물정책 수립에 활용하도록 하기 위해서 조사분석하여 다음과 같은 결과를 얻었다. 일반주택의 배출량원단위는 0.50kg/인${\cdot}$일로 배출량은 41.9톤/일, 공동주택의 배출량원단위는 0.45kg/인${\cdot}$일로 배출량은 55.5톤/일, 읍 면지역의 배출량원단위는 0.22kg/인${\cdot}$일로 배출량은 13.5톤/일로 나타나 주택지역의 생활계폐기물 배출량은 110.9톤/일이다. 재래시장의 배출량원단위는 1.85kg/상가 일로 배출량은 5,400kg/일이며, 소규모점포의 배출량원단위는 2.03kg/상가 일로 배출량은 25,101kg/일로 나타나 상가지역의 생활계폐기물 배출량은 30,501kg/일이다. 공장지역에서 배출되는 사업장생활계폐기물은 1일 평균 8.3톤, 학교와 병원 및 업무지역에서 배출되는 생활계폐기물의 1일 평균배출량은 각각 7.2kg과 3.0kg 및 6.6kg이다. 생활폐기물 중에서 음식물쓰레기는 평균 63.4톤/일 배출되었으며, 소각대상 가연성폐기물은 126.9톤/일 배출되었다. 음식물쓰레기처리시설의 내구년도를 약 5년(2006년도)으로 계획하면 처리대상량은 1일 42.4톤이 예상되며, 저부하 운전이나 고장보수로 인한 가동중지 등의 문제를 고려하여 처리능력을 25톤/일${\times}$2계열로 설치하는 것이 효율적일 것으로 판단된다. 소각처리시설의 내구년도를 약 10년(2011년도)으로 계획하면 처리대상량은 1일 150톤/일이 예상되며, 저부하 운전이나 고장보수로 인한 소각작업 중지 등의 문제를 고려하여 처리능력을 80톤/일${\times}$2계열로 설치하는 것이 효율적일 것으로 판단된다.

Keywords