Experimental Study on the Performance Characteristics of Hot-gas Bypass and On-off Defrosting Cycle in a Showcase Refrigeration System

쇼케이스에서 고온가스 바이패스 및 단속운전 제상사이클의 성능특성에 관한 실험적 연구

  • Published : 2002.06.01

Abstract

During the defrosting process, the temperature in the cabinet of a showcase becomes high as compared to the setting point, which is not desirable for stored foods or materials. It is necessary to develop a more efficient defrosting method to prevent large temperature fluctuation. In this study, the performance of a showcase refrigeration system with three evaporators is investigated by employing a hot-gas bypass defrosting technology in the system under frosting and defrosting conditions. The operating characteristics are compared with those for the on-off defrosting method that has been widely used in current products. As a result, the hot-gas bypass defrosting method shows higher refrigerating capacity and less temperature fluctuation than the on-off method under frosting/defrosting conditions, while the power input is relatively high for the hot-gas bypass method.

Keywords

References

  1. Int. J. of Refrigeration v.16 no.3 Performance of Finned-tube Heat Exchangers under Frosting Conditions: Ⅰ. Simulation Model Kondepudi, S. N.;O'Neal, D. L. https://doi.org/10.1016/0140-7007(93)90045-A
  2. Int. J. of Refrigeration v.16 no.3 Performance of Finned-Tube Heat Exchangers under Frosting Conditions: Ⅱ. Comparison of Experimental Data with Model Kondepudi, S. N.;O'Neal, D. L. https://doi.org/10.1016/0140-7007(93)90046-B
  3. ASHRAE Trans. v.96 The Effect of Different Fin Configurations on the Performance of Finned-Tube Heat Exchangers under Frosting Conditions Kondepudi, S. N.;O'Neal, D. L.
  4. Proceedings of the SAREK An Experimental and Numerical Study on the Performance Analysis of an Evaporator Used in a Domestic Freezer Lee, T. H.;Lee. J. S.;Park, J. J.;Kim, B. J.;Lee, S. W.;Yun, J. Y.
  5. Proceeding of the ASME Advanced Energy Systems Division v.AES-37 Effects of Evaporator Frosting on the Performance of an Air-To-Air Heat Pump Frias, J. M.;Aceves, S. M.
  6. Int. J. of Refrigeration v.14 Effect of Short-Tube Orifice Size on the Performance of an Air Source Heat Pump During the Reverse-Cycle Defrost O'Neal, D. L.;Peterson, K.;Anand, N. K. https://doi.org/10.1016/0140-7007(91)90022-9
  7. ASHRAE Trans. Refrigeration System Dynamics During the Reverse Cycle Defrost O'Neal, D. L.;Peterson, K. T.;Anand, N. K.;Schliesing, J. S.
  8. Proceedings of the KSME 2000 Fall Annual meeting B Frosting and defrosting characteristics of a show case system Noh, H. I.;Kim, Y.;Park, Y. C.
  9. M.S. Thesis, Experimental Study on the Performance Enhancement of Showcase Storage Temperature Control Noh, H. I.