Abstract

Cooling towers water has frequently been known as a source of infection in outbreaks of Legionnaires' disease and a source of indoor air pollution. However, there have been a few reports on the presence of Legionella in cooling towers water and aerosols of various public facilities. This study was carried out to investigate the indoor and outdoor dis-tribution of Legionella spp and microbe from 132 cooling towers water of public facilities detected 1. pneumophila in Seoul and Gyeonggi-Do areas. The results showed that the Lpneumophila among the selected 132 cooling towers was detected mostly in July (12.0%), followed by August (4.0%) and June, September no-detected. The 1. pneumophiia in public facilities was detected mostly in department store (27.3%), followed by hospital (8.7%), office building (5.9%), big market (5.0%) and hotel, subway no-detected. The pH values of cooling towers water with presence of 1. pneumophila showed mostly 8.0 or higher (9.5%), followed by 7.0~8.0 (6.8%), lower 7.0 no-detected. The tem-perature of cooling towers water with presence of L pnemophila showed mostly 30℃ or higher (9.8%), followed by 26~30℃ (6.9%), lower 25℃ no-detected. The turbidity of cooling towers water with presence of 1. pneumaphila showed mostly 1-2 M (8.8%), followed by above 2 NTU (5.9%), lower 1 NTU no-detected. The correlation coef-ficient between indoor and outdoor concentration of microbes in public facilities showed 0.67 in Legionella spy. (p>0.05), 0.93 in bacteria (p<0.01), 0.94 in fungus (p<0.01), 0.98 in coilform (p<0.01), respectively.

Keywords

References

  1. Chanpin, E. S. : Human activity patterns in the city : Things people do in time and in space. John Wiley and Sons., New York, 1974
  2. 김윤신 : 실내공기오염에 관한 보건학적 고찰. 대한보건협회지, 9(3), 27-39, 1983
  3. Yocom, J. E. : Indoor-outdoor air quality relation-ships - a critical review. JAPCA, 32, 1982
  4. 백남원, 김윤신, 김광종 : 지하공간의 공기오염 및 공기 중 미량유해물질에 관한 조사연구. 한국환경과학연구협의회, 1989
  5. 환경부 : 지하생활공간 공기질 관리법 시행규칙. 관보 13816호, 1998
  6. 서울특별시 : 지하생활공간 공기오염 저감방안에 관한 연구. 1997
  7. Fraser, D. W. : Legionnaires' disease: four summer' harvest. Am. J. Med., 68, 1-2, 1980 https://doi.org/10.1016/0002-9343(80)90151-5
  8. McDade, J. E., Shepard, C. C., Fraser, D. W., Tsai, T. R., Redus, M. A. and Dowdle, W. R. : Legionnaires disease: Isolation of a bacterium and demonstation of its role in other respiratory disease. N. Engl. J. Med., 297, 1197, 1977 https://doi.org/10.1056/NEJM197712012972202
  9. Winn, W. R. Jr. : Legionnaires' disease: Historical perspective. Clin. Microbiol, Rev., 1, 60-81, 1988 https://doi.org/10.1128/CMR.1.1.60
  10. Glick, T. H., Gregg, M. B., Berman, B., Malison, G., Phodes, W. W. and Kassanoff. Pontiac fever : An epi-demic of unknown etiology in a heath department. 1. Clinical and Epidemiologic aspects. Am. J. Epide-miol., 107, 149, 1978 https://doi.org/10.1093/oxfordjournals.aje.a112517
  11. 김정순, 이성우, 심한섭, 오대규, 조민기, 오희복, 우세홍, 정윤섭 : 1984년 7월 K병원 중환자실을 중심으로 집단발생한 비폐렴성 Legionellosis(pontiac fever)에 관한 역학적 연구. 한국역학회지, 7, 44, 1985
  12. Meers, P. D., Goh, K. T. and Lim, E. W. : Legionella species, serogroups and subgroups found in the envi-ronment in Singapore. Ann Acad Med Singapore, 18(4), 375-8, 1989
  13. 환경부 : 지하생활공간 공기질관리법. 2001
  14. Kusnetsov, J. M., Jousimies-Somer, H. R., Nev-alainen, A. L. and Martikainen, P. J. : Isolation of Legionella from water samples using various culture methods. J. Appl. Bacteriol, 76(2), 155-62, 1994 https://doi.org/10.1111/j.1365-2672.1994.tb01611.x
  15. 국립보건원 : 개정 감염병 실험실 진단지침. 1996
  16. 환경부 : 먹는물수질공정시험법 (2000.7.1개정). 2000
  17. 식품의약청안전청 : 식품공전, 2000
  18. Krieg, N. R. and Holt, J. G. : Bergey's manual of sys-tematic bacteriology. William and Wilkins, Balti-more, 498-506, 1984
  19. 박석기, 황영옥, 정지헌, 정윤태 : 서울시내 다중이용시설 냉각탑수의 레지오넬라균 분포 및 혈청학적특성. 서울시보건환경연구원보, 35, 21-26, 1999
  20. 박석기, 황영옥, 정지헌, 정윤태 : 서울시내 다중 이용시설 냉각탑수의 레지오넬라균 분포 및 혈청학적특정 (1994-1998) 서울시보건환경연구원보, 34, 10-16, 1998
  21. 정종학, 강복수, 김석범, 사공준 : 환경수(냉각탑수)로부터 Legionella속 균의 분리. 영남의대학술지, 5(1), 1988
  22. 김권범, 김우주, 김민자, 박승철, 유세화, 섬희선, 함희진, 박석기 : 서울시내 대형건물 냉각탑 수의 레지오넬라균의 오염도 조사와 분자형별 분석에 관한 연구. 감염, 30, 207-217, 1998
  23. 厚生省 生活衛生局 企劃課 : Legionellosis 防止指針. 財團法人 Building 管理敎育 Center, 1993
  24. Ikedo. Yabuuchi : Ecological studies of Legionella species. I, viable counts of Legionella pneumophila in cooling tower water, Microbiol. Immunol., 30(5) 413-423, 1986 https://doi.org/10.1111/j.1348-0421.1986.tb02967.x
  25. Feeley, J. C., Gorman, G. W., Weaver, R. E., Mackel, D. C. and Smith, H. W. : Primary isolation media for legionnaires disease bacterium. J. Clin. Microbiol., 8, 320-325, 1978
  26. Fliermans, C. B., Cherry, W. B., Orrison, L. H., Smith, S. J., Tison, D. L. and Pop, D. H. : Ecological distribution of Legionella pneumophila. Appl. Environ. Microbiol., 41, 9-16, 1981
  27. Tison, D. L., Pope, D. H., Cherry, W. B. and Fliermans, C. B. : Growth of Legionella pneumophila in association with blue-green algae(Cyanobacteria). Appl. Environ. Microbiol., 39, 456-459, 1980
  28. Pope, D. H., Soracco, R. J., Gill, H. K. and Fliermans, C. B. : Growth of Legionella pneumophila in two membered culturer with green algae and cyanobacteria. Curr. Microbil, 7, 319-322, 1982 https://doi.org/10.1007/BF01566871
  29. Leoni, P. P. and Legani : Comparison of selective procedures for isolation and enumeration of Legionella species from hot water system. J. Applied Microbioi., 90, 27-33, 2001 https://doi.org/10.1046/j.1365-2672.2001.01178.x
  30. 이용우, 성원근, 오현수, 오희복, 박미연, 이명숙, 박경식, 백승복 : Legionella spp.의 감염 및 분포에 관한 연구. 국립보건원보, 23, 297-307, 1986
  31. Capabianca, R. M., Jurinski, V. B. and Jurinski, J. B. : A comparison of Legionella and other bacteria concentrations in cooling tower water. Appl. Occup. Environ. Hyg., 9(5), 358-361, 1994 https://doi.org/10.1080/1047322X.1994.10388327