An Experimental Study of a Slab Wick Heat Pipe for Medium-high Operating Temperatures

중온 작동 범위에서의 슬랩윅 히트파이프 성능에 관한 실험 연구

  • 정복원 (한국항공대학교 항공우주 및 기계공학부 대학원) ;
  • 부준홍 (한국항공대학교 항공우주 및 기계공학부) ;
  • 곽희열 (한국에너지기술연구원)
  • Published : 2002.11.01

Abstract

A slab-wick heat pipe was fabricated and tested for applications where the condenser temperature is in a range of 80 to 12$0^{\circ}C$. The pipe material was 9.53 mm O.D. copper tube and the working fluids were ethanol and water. The total length of the heat pipe was 1.6 m, in which evaporator section was 1.4 m and the condenser was 0.10 m. The slab was a composite wick structure fabricated with STS316 wire screens. Thermal load was varied for a specified fill charge ratio and inclined angle. The optimum fill charge ratio was identified to be 110% based on a theoretical calculation of the pore space in the slab wick of the heat pipe. The maximum thermal load was 120W for ethanol and the same was 200W for water with the condenser temperature of 8$0^{\circ}C$. The thermal performance of the slab wick heat pipe is analysed in terms of temperature characteristics and thermal resistance against thermal load, tilt angle and fill charge ratio.

Keywords

References

  1. Faghri, A., 1995, Heat Pipe Science and Technology, Taylor & Francis, pp. 24-32
  2. Peterson, G. P., 1994, An Introduction to Heat Pipes - Modeling. Testing and Applications, Wiley- Interscience, pp. 241-246
  3. Chang, W. S. and Cowell, G. T., 1985, 'Mathematical Modeling of the Transient Operating Characteristics of a Low-Temperature Heat Pipe,' Numerical Heat Transfer, Vol. 8. pp. 169-186 https://doi.org/10.1080/01495728508961848
  4. Boo, J. H. and Hartley, J. G., 1990, 'Analysis of the Thermal Performance of Heat Pipe Radiators,' Presented at the AIAA/ASME Thermophysics and Heat Transfer Conference, Seattle, Washington, U.S.A., ASME HTD Vol. 135, pp. 25-32
  5. Yim, K. B. and Kim, C. J., 1993, 'A Study on Design and Performance of a Heat Pipe for the Application to Solar Collector,' Journal of The Korea Society for Energy Engineering, Vol. 2, No. 2, pp. 179-186
  6. Kim, C. J. and Yim, K. B, 1993, 'An Experimental Study on the Heat Transfer Characteristics for a Flat Plate Solar Collector with a Heat Pipe,' Journal of The Korea Society for Mechanical Engineering, Vol. 17, No. 5, pp. 1237-1245
  7. Chi, S. W., 1976, Heat Pipe Theory and Practic: A Sourcebook, Hemisphere Publishing Corp., pp. 197-210
  8. Lock, G. S. H., 1992, The Tubular Thermosyphon, Oxford University Press, pp. 132-153