DOI QR코드

DOI QR Code

Estimation of Flaw Depth and Height by Radiography

방사선투과사진에 의한 결함깊이 및 높이의 평가

  • 강계명 (서울산업대학교 신소재공학과) ;
  • 박은수 (서울산업대학교 신소재공학과) ;
  • 심언덕 (동양검사기술(주))
  • Published : 2002.08.01

Abstract

The three-dimensional estimation on the depth and height of flaw by using the difference of radiographic contrast density was studied. First, the specimens having artificial flaws of various depths and heights were prepared and the radiographic testing was performed. The radiographic depth of flaw was investigated and estimated on the effect of the scattered radiation with the change of distance between flaw and film. The height of flaw was estimated from the radiographic test with the reference specimen. The radiographic contrast with flaw depth decreased with increasing the flaw depth. The scattered radiation increased with increasing flaw depth and varied with the location between flaw and film. However, in the case of flaw height, the contrast density increased with increasing flaw height. It is thought due to the change in volume generating the scattered radiation which reaches a film.

Keywords

References

  1. Metal handbook, 9th ed., Nondestructive Evaluation and Quality Control. ASTM International, 17, 310 (1996)
  2. Lawrence E. Bryant, Nondestructive Testing Handbook, ASNT, 3, 317 (1985)
  3. Radiograpy in Modern Industry, 4th ed., Eastman Kodak Company, 114 (1980)
  4. 中村和夫, 平山一男, 橋本健二, 中村正宏, 加藤光昭, 日本非破壞檢査協會, 48(7), 421 (1999)
  5. 中村和夫, 平山一男, 橋本健二, 中村正宏, 加藤光昭, 日本非破壞檢査協會, 48(7), 430 (1999)
  6. 中村和夫, 平山一男, 橋本健二, 中村正宏, 加藤光昭, 日本非破壞檢査協會, 48(7), 437 (1999)
  7. 仙田富男, 平山一男, 山中久志, 橫山計次, 中村知夫, 日本非破壞檢査協會, 36(6), 411 (1987)
  8. Glenn F. Knoll, Radiation Detection and Measurement, Hemisphere, 50 (1989)
  9. 仙田富男, 平山一男, 小野桂一郞, 高橋次郞, (社)日本非破壞檢査協會關西支部硏究發表會, 65 (1979)
  10. B.D. Cullity, Elements of X-ray Diffraction, 2nd ed., Addison Wesley, 13 (1977)
  11. Nicholas Tsoulfanidis, Measurement and Detection of Radiation, John Wiley & Sons, 141 (1976)