Development of Real-Time Thickness Measuring System for Insulated Pipeline Using Gamma-ray

감마선을 이용한 단열배관의 실시간 두께측정시스템 개발

  • 장지훈 (한국기계연구원 비파괴평가그룹) ;
  • 김병주 (한국기계연구원 비파괴평가그룹) ;
  • 김기동 (한국지질자원연구원 입자빔응용팀) ;
  • 조경식 (한국기계연구원 비파괴평가그룹)
  • Published : 2002.10.30

Abstract

By this study, on-line real-time radiometric system was developed using a 64 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses an Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer through cable. This system collects and analyses the data from the detector array in real-time as the crawler travels over the piping system. The maximum measurable length of pipe is 120cm/min. in the case of 1mm scanning interval.

본 연구에서는 감마선과 섬광체 및 광 다이오드로 구성된 64 채널의 선형 디텍터 어레이를 이용하여 보온재로 싸인 배관의 두께를 실시간으로 측정하는 시스템을 개발하였다. 본 측정시스템은 감마선원으로 Ir-192를 사용하였으며, 디텍터는 BGO 섬광체와 광다이오드로 구성하였다. Ir-192 방사선원은 배관의 한쪽 편에, 그리고 디텍터 어레이는 배관을 중심으로 그 반대편에 위치하며 컴퓨터로 제어되는 주행 시스템에 실려 배관을 따라 이송되는 동안 배관과 단열재를 투과한 방사선의 강도는 각 디텍터에서 측정된다. 측정된 디텍터 어레이의 출력은 증폭기에서 증폭된 후 케이블에 의해 컴퓨터로 전송되며 주행시스템이 진행하는 동안 컴퓨터는 수집된 신호를 분석 및 계산하여 실제의 두께를 나타내며 주사간격을 1mm로 할 경우의 최대 측정속도는 분당 120cm이다.

Keywords

References

  1. Nand K. Gupta and Bruce G. Issacson, 'Real Time In-Service Inspection of Bare Insulated Above-Ground Pipelines,' Materials Evaluation, Vol. 55, No. 11, pp. 1219-1225, (1997)
  2. Andreas Hecht et al., 'On-Line Radiographic Wallthickness-Measurement of Insulated Piping in the Chemical and Petrochemical Industry,' 7th European Conference on Non-destructive Testing, (ndt.net)(1998)
  3. J. M. Galbraith et al., 'Real-titre Radioscopic Inspection of Insulated Piping Systems,' Insight, Vol. 37, No. 6, pp. 417-420, (1995)
  4. D. E. Groom, Nucl. Inst. and Meth. in Physics Research 219, pp. 141-148, (1984)
  5. S. E. Derenzo, Nucl. Inst. and Meth. in Physics Research 219, pp. 117-122 (1984)
  6. BICRON, Scintillation Detector, (Manual)(1999)
  7. Hammatsu, Si Photodiodes and Charge Sensitive Amplifiers for Scintillation Counting and High Energy Physics, (Manual)(1999)
  8. Nicholas Tsoulfanidis, 'Measurement and Detection of Radiation', Chap. 4, pp. 115-164, Hemisphere Publishing Corp, U.S.A. (1983)
  9. Glenn F. Knoll, 'Radiation Detection and Measurement', Second Edition, Vol. 1, Chap.10, pp. 307-353, John Wiley & Sons, U.S.A. (1989)
  10. Kai Siegbahn, 'Alpha-, Beta- and Gamma-ray Spectroscopy', Vol. 1, Chap. 1, North-Holland Publishing Company, (1966)