Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room

CFD해석에 의한 침실 호흡역의 환기효율 분석

  • Published : 2002.10.31

Abstract

Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

Keywords

References

  1. 김용경, 정순성, 권양구,이정재(1999), 환기효율의 정량적 평가를 통한 필요환기량 산정방법에 관한 연구(제1보). 대한건축학회학술발표논문집, 19(1), pp 593-598
  2. 박진민, 이경희(1993), 건강환기를 교려한 사무소 건물의 실내 공기오염도 예측에 관한 연구, 대한건축학회학술발표논문집,13(2), pp 333-336
  3. 김정태, 노지웅, 정유근(1999), 공동주택 주방의 레인지후드 환기효율에 관한 현장 실험, 대한건축학회논문집, 15(1), pp 207-214
  4. 조우진, 윤동원, 손장열, 이승민(1999), 공기조화에서 공기취출방식에 따른실내공간의 환기효율 및 온도분포 특성평가, 대한건축학회논문집 15(4), pp 205-212
  5. 이정재(1995), 실내농도분포의 고정도 수치예측법에 관한 연구, 대한건축학회논문집 11(11), pp 163-169
  6. 조우진, 윤동원, 손장열, 문현준(1998), 공조설비 취출방식에 따른 환기효율 평가에 관한 연구, 대한건축학회학술발표논문집, 18(2), pp 817-822
  7. 村土周三, 加藤信介(1986), 新たな換氣效率指標と 三次亂流數値シミュレ-ションによる計算法, 空氣調和.衛生工學會論文集, No.32, pp 91-102
  8. 桑原亮一, 赤林伸一, 水谷國男, 佐藤英樹(1993), 事務室における空調方式と換氣效率に關する檢討:建物の空調.換氣效率に關する硏究 その1, 日本建築學計劃系論文集, 第517号, pp29-36
  9. 赤林伸一, 坂口 淳, 村土周三, 加藤信介, 深尾仁, 長谷川 功, 須山喜美(1999), ォフィスビルを對象とした換氣效率に關する實測調査:オフィスビルを對象とした換氣效率に關する硏究その1, 日本建築學會計劃系論文集, 第516号, pp39-46
  10. 近藤靜史, 吉野 一, 今井智浮, 田所祐入, 橫田雄史(2001),實測およびCFD解析による地下駐車場內の換氣性狀の檢討:地下駐車場の換氣性狀.換氣效率に關する硏究, 第549号, pp 37-44
  11. 赤林伸一,桑原亮一,永谷國男, 何 平, 佐藤英樹(2000), アトリウム空間を對象とした空調方式と換氣效率に關する檢討:建物の空調.換氣效率に關硏する究その1. 日本建築學會計劃系論文集, 第517号, pp 45-50
  12. 赤林伸一, 坂口 淳(1998), 漏入空氣の影響を考慮した 換氣效率指標の算出方法:住宅の換氣システムに關する 硏究 その2, 第512号, pp 33-37
  13. 伊藤一秀, 加藤信介, 村土周三(2000), 換氣效率指標の數値解析檢証用の2次元室內氣流實驗:不完全混合室內の居住域換氣效率の評價に關する硏究,第534号,pp 49-56
  14. 桑原亮一, 何 平, 山田義昭, 水谷國男(1999), 換氣效率指標の設計應用に關する檢討 (空調.換氣效率に關する硏究 その5), 建設備工業(株) つくば總合硏究所硏究報告No.6