A COMPARATIVE STUDY ON THE ACCURACY OF MASTER CASTS BY IMPLANT IMPRESSION TECHNIQUES

치과 임플랜트 인상채득 방법에 따른 주모형의 정확성에 대한 비교 연구

  • Rhyu Seok-Min (Department of Prosthodontics, College of Dentistry, Dankook University) ;
  • Cho In-Ho (Department of Prosthodontics, College of Dentistry, Dankook University) ;
  • Lim Heon-Song (Department of Prosthodontics, College of Dentistry, Dankook University) ;
  • Lim Ju-Hwan (Department of Prosthodontics, College of Dentistry, Dankook University)
  • 류석민 (단국대학교 치과대학 보철학교실) ;
  • 조인호 (단국대학교 치과대학 보철학교실) ;
  • 임헌송 (단국대학교 치과대학 보철학교실) ;
  • 임주환 (단국대학교 치과대학 보철학교실)
  • Published : 2002.02.01

Abstract

As the inaccuracy which was made in implant impression prevented passive fit, it needed to solder the sectioned framework at several locations to correct the inaccuracy. Many clinicians have suggested impression techniques which could make passive fit between implant and superstructure. The purpose of this research was to measure and compare the accuracy of three methods of taking impression with the strain amplifier. The experimental groups were classified as follows : Group I : splinted the two parts with $Futar^{(R)}D$ Occlusion. Group II : splinted the two parts with $DuraLay^{(R)}$. Group III ; didn't splint the two parts. The results were as follows ; 1. The values of strain in the vertical and horizontal surfaces were increased in the order of group I, group II and group III. 2. Group 1 showed higher accuracy of the duplicated casts in the vortical and horizontal sur faces than group II and group III (p<0.05). 3. There were no significant differences in the accuracy of the duplicated casts between group II and group III. From the above results, it is considered that the splinting method of impression copings could make an influence on the accuracy of the master casts. To improve the accuracy of the master casts, splinting the squared impression copings with the additional silicone occlusion materials is recommendable.

Keywords

References

  1. Adell, R., Lekholm, U., Rockier. B., and Branemark, P.I. : A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int. J. Oral. Surg., 10:387-416, 1981
  2. Albrektsson, T. : A multicenter report of osseointegrated oral implant. J. Prosthet. Dent., 60:75-84, 1988
  3. Friberg, B., Jemt. T., and Lekholm, U, : Early failure in 4,641 consecutively placed Br${\aa}$nemark dental implant: A study from stage 1 surgery to the connection of completed prostheses. Int. J. Oral Maxillofac. Implants, 6:142-146, 1991
  4. Jaffin. R., and Berman, C. : The excessive loss of Br${\aa}$nemark implant in type IV bone: A 5-year analysis. J. Periodontol. 62:2-4, 1991
  5. Branemark, P.I. : Osseointegration and its experimental background. J. Prosthet. Dent., 50:399-410, 1983
  6. Hobo, S., Ichida, E., and Garcia, U. : Osseointegration and occlusal rehabilitation. Quintessence, 153-159, 1990
  7. Skalak, R. : Biomechanical consideration in osseointegrated prostheses. J. Prosthet. Dent., 49: 843-848, 1983
  8. Zarb, G.A., Branemark, P.I., and Albrektsson, T. : Tissue-integrated prostheses : Osseointegration in clinical dentistry. Chicago, Quintessence Pub. Co., 293-299, 1985
  9. Sones, A.D. : Complication with osseointegrated implant. J. Prosthet. Dent. 62: 581-585, 1989
  10. Worthington, P., Bolendef, C.L., and Taylar, T.D. : The Swedish system of osseointegrated implants : problems and complications encountered during a 4year trial period. Int. J. Oral Maxillofac. Implants, 2:77-84, 1987
  11. Zarb, G.A., and Zarb, F.L. : Tissue integrated dental prostheses. Quintessence Int., 1: 39-42, 1985
  12. Sellers, G.C. : Direct assembly framework for osseointegrated implant prosthesis. J. Prosthet. Dent., 62:662-668, 1989
  13. Henry, P.J. : An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. J. Prosthet. Dent., 58:694-697, 1987
  14. Tautin, F.S. : Impression making for osseointegrated dentures. J. Prosthet. Dent., 54:250-251, 1985 https://doi.org/10.1016/0022-3913(85)90299-9
  15. Clelland, N.L., Carr, A.B., and Gilat, A. : Comparison of strains transferred to a bone simulant between as-cast and post-soldered implant frameworks for a five-implant-supported fixed prosthesis. J. Prosthodont., 5(3):193-200, 1996 https://doi.org/10.1111/j.1532-849X.1996.tb00296.x
  16. Tan, K.B., Rubenstein, J.E., and Nicholls, J.I. : Three-dimensional analysis of the casting accuracy of one piece. osseointegrated implant-retained prostheses. Int. J. Prostho., 6:346-363, 1993
  17. Carr, A.B. : A comparison of impression techniques for a five implant mandibular model. Int. J. Oral. Maxillofac. Implants. 6: 448-455, 1991
  18. Humphries, R.M., yaman, P., and Bloem, T.J. : The accuracy of implant master casts constructed from transfer impressions. Int. J. Oral Maxillofac. Implants. 5:331-336, 1990
  19. Phillips, K.M., Nicholls. J.I., Ma, T., and Rubenstein, J. : The accuracy of three implant impression technique : A three-dimensi onal analysis. Int. J. Oral Maxillofac. Implant, 9:533-540, 1994
  20. Rodney. J., Johansens, R., and Harris, W. : Dimensional accuracy of two implant impression copings. J. Dent. Res., 70:385, 1991
  21. Assif, D., Marshak, B., and Nissan, J. : A modified impression technique for implant-supported restoration. J. Prosthet. Dent., 71: 589-591, 1994
  22. Burawi. G., Houston, F., Byrne, D., and Claffey. N. : A comparison of the dimensional accuracy of the splinted and un splinted impression techniques for the Bone-Lock implant system. J. Prosthet. Dent., 77: 68-75, 1997
  23. Hussaini, S., and Wong, T. : One clinical visit for a multiple implant restoration master cast fabrication. J. Prosthet. Dent., 78: 550-553, 1997
  24. Shiau, J.C., Chen, L.L., and Wu, C.T. : An accurate impression method for implant prostheses fabrication. J. Prosthet. Dent., 72:23-25, 1994 https://doi.org/10.1016/0022-3913(94)90211-9
  25. Liou, A.D., Nicholls. J.I., Yuodelils, R., and Brudvik, J.S. : Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. Int. J. Prosthodont., 6:377-383, 1993
  26. Wee, A.G. : Comparison of impression materials for direct multi-implant impressions. J. Prosthet. Dent., 83(3):323-331, 2000
  27. Misch, C.E. : Density of bone: effect on treatment plans. surgical approach. healing. and progressive loading. Int. J. Oral Maxillofac. Implants. 10:303-311, 1995
  28. Zarb, G.A., and Schmitt, A. : The longitudinal clinical effectiveness of osseointegrated implants. the Toronto study. Part ill: Problems and complications encountered. J. Prosthet. Dent., 64:185-196, 1990
  29. 김용재, 조인호: 치과 임플랜트 인상 코핑 및 인상재의 종류에 따른 주모형의 정확성에 관한 연구, 대한치과이식학회지, 14(1):59-70, 1994
  30. 이병화, 조인호 : 치과 임플랜트 인상 코피의 고정 방법에 따른 주모형의 정확도에 관한연구. 단국치대 논문집. 1995
  31. Assif, D., Fenton, A., Zarb, G., and Schmitt, A. : Comparative accuracy of implant impression procedures. Int. J. Periodont. Rest. Dent., 12:113-121, 1992
  32. Barrett, M.G., Rijk, W.G., and Burgess, J.O. : The accuracy of six impression techniques for osseointegrated implants. J. Proshodont., 2(2):75-82, 1993 https://doi.org/10.1111/j.1532-849X.1993.tb00387.x
  33. Misch, C.E. : Principles for screw retained prostheses in contemporary implant dentistry, St Louis, Mosby, 669-685, 1993
  34. Assif, D., Marshak. B., and Schmidt, A. : Accuracy of implant impression techniques. Int. J. Oral Maxillofac. Implants, 11:216-222, 1996
  35. Assif, D., Nissan, J., Varsano. I., and Singer. A. : Accuracy of implant impression splinted technique: effect of splinting material. Int. J. Oral Maxillofac. Implants, 14:885-888, 1999
  36. Inturregui, J.A., Aquilino, S.A., Ryther, J.S., and Lund, P.S. : Evaluation of three impression techniques for osseointegrated oral implants. J. Prosthet. Dent., 69: 503-509, 1993
  37. Hsu, C.C., Millstein, P.L., and Stein, RS. : A comparative analysis of the accuracy of implant transfer techniques. J. Prosthet. Dent. 69: 588-593, 1993
  38. Mojon, P., Oberholzer, J.P., Meyer, J.M., and Belser, U.C. : Polymerization shrinkage of index and pattern acrylic resins. J. Prosthet. Dent., 64(6):684-688, 1990
  39. Spector, M.R, Donovan, T.E., and Nicholls, J.I. : An evaluation of impression technique for osseointegrated implants. J. Prosthet. Dent., 63:444-447, 1993