Optimal Design of a Flextensional Transducer Considering All the Cross-coupled Effects of the Design Variables

설계변수들의 상호효과를 고려한 Flextensional 트랜스듀서의 최적설계

  • Published : 2003.05.01

Abstract

The performance of an acoustic transducer is determined by the effects of many design variables. and mostly the influences of these design variables are not linearly independent of each other To achieve the optimal performance of an acoustic transducer, we must consider the cross-coupled effects of the design variables. In this study with the FEM. we analyzed the variation of the resonance frequency and sound pressure of a flextensional transducer in relation to Its design variables. Through statistical multiple regression analysis of the results, we derived functional forms of the resonance frequency and sound pressure in terms of the design variables, and with which we determined the optimal structure of the transducer by means of a constrained optimization technique, SQP-PD. The proposed method can reflect all the cross-coupled effects of multiple design variables, and can be utilized to the design of general acoustic transducers.

Keywords

References

  1. Oswin, J. R. and Dunn, J., 1988, "Frequency, Power and Depth Performance of Class IV Flextensional Transducers," in: B. Hamonic and J. N. Decarpigny (Eds.). Power Sonics and Ultrasonic Transducers Design, Springer-verlag. Berlin.
  2. Dufourcq, P., Adda. J., Letiche, M. and Sernit, E., 1991, "Transducers for Great Depths," in : B. Hamonic, O. B. Wilson, and J. N. Decarpigny (Eds.), Power Transducers for Sonics and Ultrasonics, Springer-verlag, Berlin.
  3. Romdhane, M., Gadri. A., Contamine, F., Gourdon, C. and G. Casamatta, 1997, "Experimental Study of the Ultrasound Attenuation in Chemical Reactors," Ultrasonics Sonochemistry, Vol. 4, No. 3, pp. 235-243. https://doi.org/10.1016/S1350-4177(97)00002-3
  4. Hanel, R., Mues, A. and Sobotta, R., 1996, "Description of Ultrasound Transducers Through Wave Parameters." Ultrasonics, Vol. 34. pp. 159-162. https://doi.org/10.1016/0041-624X(96)81779-3
  5. McKeighen, R. E., 1996. "Optimization of Broadband Transducer Designs by use of Statistical Design of Experiments," IEEE Trans. on UFFC, Vol. 43. No. 1, pp. 63-70. https://doi.org/10.1109/58.484464
  6. Butler, S. C., Butler, J. L., Butler, A L. and Cavanagh. G. H., 1997. "A Low-frequency Directional Flextensional Transducer and Line Array," J. Acoust. Soc. Am., Vol. 102. No. 1, pp. 308-314. https://doi.org/10.1121/1.419609
  7. Rolt, K. D., 1990. "History of the Flextensional Electroacoustic Transducer." J. Acoust. Soc. Am., Vol. 87, No. 3, pp. 1340-1348. https://doi.org/10.1121/1.399507
  8. Oswin, J. R. and Turner, A., 1984, "Design Limitations of Aluminium Shell. Class IV Flextensional Transducers," Proc. Inst. Acoustics, Vol. 6. No. 3, pp. 94-101.
  9. Boucher. D., 1988. "Trends and Problems in Low Frequency Sonar Projectors Design," in: B. Hamonic and J. N. Decarpigny (Eds.), Power Sonics and Ultrasonic Transducers Design. Springer-verlag, Berlin.
  10. Moffett, M. B., Clark, A. E., Wun-Fogle, M., Linberg, J., Teter, J. P. and McLaughlin, E. A., 1991. "Characterization of Terfenol-D for Magnetostrictive Transducers." J. Acoust. Soc. Am., Vol. 89, No. 3. pp. 1448-1455. https://doi.org/10.1121/1.400678
  11. Houqing, Z., Jianguo, L., Yanhong, X., Xiurong, W. and Hongping, Z., 1997, "Applications of Terfenol-D in China," Journal of Alloys and Compounds, Vol. 258, pp. 49-52. https://doi.org/10.1016/S0925-8388(97)00068-6
  12. Hom, C. L. and Shankar, N., 1998, "Modeling Nonlinearity in Electrostrictive Sonar Transducers," J. Acoust. Soc. Am., Vol. 104, No. 4, pp. 1903-1913. https://doi.org/10.1121/1.423761
  13. Kuehl, R. O., 2000, Design of Experiments: Statistical Principles of Research Design and Analysis, Duxbury Press, Pacific Grove.
  14. Freund R. J. and Wilson, W. J., 1998, Regression Analysis: Statistical Modeling of a Response Variable, Academic Press, San Diego.
  15. Belegudu, A. D. and Chandrupatla, T. R., 1999, Optimization Concepts and Applications in Engineering, Prentice Hall, New Jersey.
  16. Francis, D. T. I., Oswin, J. R. and Macey, P. C., 1996, "Comparing FE/BE Models with Measurement : Flextensional Transducers," Proc. Inst. Acoustics, Vol. 18. No. 10. pp. 31-40.
  17. Wilson, O. B., 1988, Introduction to Theory and Design of Sonar Transducers, Peninsula, Los Alto.
  18. Petzing, J. N., Tyrer, J. R. and Oswin, J. R. 1996, "Improved Interferometric Techniques for Measuring Flextensional Transducer Vibration Patterns Underwater," Journal of Sound and Vibration. Vol. 193, No. 4, pp. 877-890. https://doi.org/10.1006/jsvi.1996.0320
  19. Debus, J. C., Hamonic, B. and Damiri, B., 1994, "Analysis of a Flextensional Transducer Using Piece-Part Equivalent Circuit Models: Determination of the Shell Contribution," Proc., IEEE Oceans'94, No. 2, pp. 289-294.
  20. Kinsler, L. E., Frey. A. R., Coppens, A. B. and Sanders, J. V., 2000, Fundamentals of Acoustics, John wiley & Sons, New York.
  21. Onitsuka, K., Dogan, A., Xu, Q., Ysohikawa, S. and Newnham, R. E., 1994. "Design Optimization for Metal-ceramic Composite Actuator. 'Moonie.' " Ferroelectrics, Vol. 156. pp. 37-42. https://doi.org/10.1080/00150199408215924
  22. SAS Institute Inc., 2000, Strategic Application Software, Ver. 8.1, Cary, North Carolina.
  23. Beranek, L. L., 1988, Acoustics. American Institute of Physics. New York.