Stator Winding Fault Diagnosis in Small Three-Phase Induction Motors by Park's Vector Approach

Park's Vector 기법을 이용한 소형 3상 유도 전동기의 권선 고장 진단

  • 박규남 (국립순천대학교 전기공학과) ;
  • 한민관 (국립순천대학교 전기공학과) ;
  • 우혁재 (국립순천대학교 전기공학과) ;
  • 송명현 (국립순천대학교 전기공학과)
  • Published : 2003.11.01

Abstract

This paper deals with efficient diagnostic for stator winding fault of 3-phase induction motor using a current Park's vector approach. This method firstly transforms 3-phase stator current to vertical axis current and horizontal axis current of Park's Vector, and then obtains the each Park's Vector Pattern and detects stator winding fault by comparing to Park's Vector Pattern of healthy and fault. Experimental results, obtained by using induction motor having inter-turn fault of 2, 10, 20 turn, demonstrate the effectiveness of the proposed technique, for detecting the presence of stator winding fault under 25%, 50%, and 100% of full load condition.

본 연구는 3상 소형 유도전동기의 고정자 권선 고장의 효과적인 진단을 위하여 고정자 전류에 대하여 Park's Vector 기법을 적용하였다. 본 기법은 고정자 3상 전류를 측정하여 Park's vector 변환을 통하여 직축, 횡축 전류로 변환하고, 이를 이용하여 고장 진단을 위한 Park's Vector Pattern을 얻어 정상 상태 패턴과 고장 권선 패턴을 비교하였다. 고정자 권선 한 상에 2턴, 10턴, 그리고 20 턴의 단락고장을 발생시켜 정격부하의 25%, 50%, 100% 부하변동에 따른 각각의 Park's Vector Pattern을 비교하여 얻은 실험 결과는 제안한 방법의 유용성을 보여준다.

Keywords

References

  1. W. T. Thomson, Mark Fenger, 'Current signature analysis to detect induction motor faults', IEEE Industry Application Amgazine, pp. 26-34. July/August 2001
  2. A. H. Bonnett, and G. C. Soukup, 'Cause and analysis of stator and rotor failues in three-phase squirrel-cage induction motors', IEEE Transactions on Industry Applications, vol. 28, no.4, pp. 921-937, July/August 1992 https://doi.org/10.1109/28.148460
  3. S. Williamson, and K. Mirzoian, 'Analysis of cage induction motors with stator winding fault,' IEEE Transactions on Power Apparatus and Systems, vol. PAS-104, no.7, pp. 1838-1842, July 1985 https://doi.org/10.1109/TPAS.1985.319221
  4. J. Penman, H .G. Sedding, B. A. Lloyd, and W. T. Fink, 'Detection and location of interturn short circuits in the stator windings of operating motors,' IEEE Transactions of Energy Conversion, vol.9 no.4 pp.652-658, December 1994 https://doi.org/10.1109/60.368345
  5. R. A. Leonhard, and W. T. Thompson, 'Vibration and stray flux monitoring for unbalanced supply and inter-tum winding fault diagnosis in induction machines,' British Joural of Nondestructive testing. pp.21l-215, July 1986
  6. F.Filippetti, G. Franceschini, C. Tassoni, A. Omettoand, and S. Meo, 'A simplified model of induction motor with stator shorted turns oriented to diagnostics,' Proceedings of the International Conference on Electrical Machines, vol. 3, pp. 410-413, 1996
  7. R. M. Tallam, T. G. Habetler, and R .G. Harley, 'Transient model for induction machines with stator winding turn fault,' Conference Records of IEEE-IAS Annual Meeting, vol. 1, pp.304-309, October 2000
  8. G. B. Kliman, W. J. Premerlani, R. A. Koegl, and D .Hoeweler, 'A new approach to on-line turn fault detection in AC motors,' Conference Records IEEE-IAS Annual Meeting, vol. 1, pp.687-693, 1996
  9. J. Sottile, and J. L. Lohler, 'An on-line method to detect incipient failure of turn insulation in random-wound motors,' IEEE Transactions on Energy Conversion, vol. 28, no.5 pp. 1109-1117, September/October 1992
  10. A. J. M. Cardoso et al., 'Inter turn stator winding fault diagnosis in three phase induction motors, by Park's Vector approach,' IEEE Trans. Ind Applicat., vol. 29 no.3, pp.595-598, Sept. 1999
  11. A .J. M. Cardoso et al,' Computer-aided detection of airgap eccentricity in operating three-phase induction motors by park's vector approach,' IEEE Trans. Ind. Applicat., vol 29, pp. 897-901, Sept./Oct. 1993 https://doi.org/10.1109/28.245712
  12. Filippetti, C, Franceschini, G, Tassoni, F, and Vas, P 'Integrated condition monitoring and diagnosis of electrical machines using minimum configuration artificial intelligence' Proceedings of EPE97, 1997, Vol 2, pp. 983-988