Abstract

The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.

Keywords

References

  1. 이성, '투명단열된 불투명 외피에서의 에너지 흐름'. 태양에너지학회논문집, Vol16. No.3 1996
  2. 김세환, 김삼열, 이성, '투명 단열외피를 통한 환기효과에 관한 연구', 태양에너지학회논문집 Vol. 20. No 4. 2000
  3. 유승호, 윤용진 '투과형 단열시스템의 투과 및 단열특성 평가' 대한건축학회계획계논문집 18권4호, 2002. 4
  4. A. Beck, M. Reim, W. Korner, J. Fricke, 'Highly Insulating Aerogel Glazing', EuroSun 2000
  5. Bruno Peuportier, Jacques Michel., 1995, 'Comparative Analysis of Active and Passive Solar Heating Systems with Transparent Insulation' Solar Energy, Vol.54, No.1. pp13-18 https://doi.org/10.1016/0038-092X(94)00112-Q
  6. A, Haller, H-J. Althaus, 'Gain Control for Solar Wall Heating With Transparent Insulation(TI) Requirements for Cost Effecctive Applications of Natural Ventilation in Multi-functional and Ventilated Facades(MFVF), EuroSun 2000
  7. Liisa Rautiainen, 'Transparent Thermal Insulation(TIM)-Performance properties', ETTR-research program funding by Ministry of Trande and Industry Energy Department. 1992