DOI QR코드

DOI QR Code

Experimental and Analytical Study on Burst Pressure of a Steam Generator Tube with a T-type Combination Crack

T-형 복합 균열이 존재하는 증기발생기 전열관의 파열압력 시험 및 해석

  • Published : 2004.02.01

Abstract

Steam generator tubes experience widespread degradations such as stress corrosion cracking, wear, tube rupture, denting, fatigue and so on. The resulting damages can cause tube bursting or leak of the primary water which contains radioactivity Therefore the allowable size of the damage is required to be determined on the maintenance purpose. The burst pressure of a tube with a T-type combination crack consisting of longitudinal and circumferential cracks is obtained experimentally and analytically. Fracture parameters such as stress intensity factor and crack opening angle are investigated. Also the burst pressure for a T-type combination crack is compared with that of a single longitudinal crack to develop a length-based criteria.

Keywords

References

  1. McDonald, P. E., Shah, V. N., Ward, L. W. and Ellison, P. G., 1996, 'Steam Generator Tube Failures,' NUREG CR-6365
  2. Frederick, G. and Hernalsteen, P., 1985, 'Tube sheet and Expansion Transition Cracking at Doel 3 and Tihange,' EPRI Workshop in Primary Side SCC, San Diego
  3. Emery, A. F., Perl, M, Love, W. J. and Kobayashi, A. S., 1981, 'On the Motion of an Axial Through Crack In a Pipe,' Journal of Pressure Vessel Technology, Vol. 103, pp. 281-286 https://doi.org/10.1115/1.3263402
  4. Shin, Kyu-In, Park, Jai-Hak, Kim, Hong-Deok and Chung, Han-Sub, 2001, 'Analysis of the Burst Pressure of Cracked S/G Tubes,' Nuclear Engineering and Design, Vol. 214, pp. 91-101 https://doi.org/10.1016/S0029-5493(02)00018-3
  5. Park, M.K., Kim, Y.J., Jheon, J.H., Kim, J.M., and Park, J.S., 1996, 'Study on Plugging Criteria for Thru-wall Axial Crack in Roll Transition Zone of Steam Generator Tube,' Transactions of KSME A, Vol. 20, No. 9, pp. 2894- 2900
  6. Lee, J.H. and Je, Y.S., 1999, 'Finite Element Analysis of Eddy-Current Nondestructive Evaluation for Steam Generator Tubes,' Transactions of KSME A, Vol. 23, No. 3, pp. 512-519
  7. EPRI TR-107569-V1R5, 1997, 'PWR Steam Generator Examination Guidelines : Revision 5.
  8. EPRI TR-016743-V4R1, 1997, 'Guidelines for PWR Steam Generator Tubing Specification and Repair
  9. EPRI TR-107620, 1998, 'Steam Generator in Situ Pressure Test Guidelines
  10. Chung, Han-Sub, Kim, Ki-Tae and Kim, Hong-Deok, 2000, 'A Study on the Integrity Assessment of Defected S/G Tube,' KEPRI TR.96NJ14
  11. EPRI TR-105505, 1997, 'Steam Gneerator Management Project; Burst Pressure Correlation for Steam Generator Tubes with Throughwall Axial Cracks
  12. EPRI NP-6865-L, 1991, 'Steam Generator Tube Integrity, Volume 1 : Burst test results and validation of rupture criteria
  13. EPRI NP-7474, 1993, 'Evaluation of Leak and Burst Characteristics of Roll Transitions Containing Primary Water Stress Corrosion Cracks
  14. Zahoor, A., 1990, 'Ductile Fracture Handbook Volume 2,' EPRI
  15. Shih, C. F., deLorenzi, H. G. and Andrews, W. R., 1979, 'Studies on Crack Initiation and Stable Crack Growth,' ASTM STP 668, pp. 65-120