A Study on the Characteristics of Internal and External Pressure Variation for KTX

KTX차량 내외부의 압력변동 특성에 관한 연구

  • 남성원 (한국철도기술연구원 공기유동연구그룹)
  • Published : 2004.03.01

Abstract

A study is conducted to clarify internal and external pressure variation of passenger cabin for KTX. These pressure variation may give rise to the ear-discomfort for passenger and fatigue for carbody. In this study, the pressure variation of interior, gangway and exterior of KTX passenger car is measured by using the atmospheric pressure sensors and portable data acquisition system. The tunnel from 4000m to 200m in length are chosen far the investigation of tunnel length effects. From the results of experiment, the pressure variation of interior per second is under the ear-discomfort limitation in all of tunnel. And, We found that there are similar patterns of exterior pressure variation for each critical tunnel length. These results generally agree to RTRI's experimental result fur Shinkansen.

Keywords

References

  1. J.Matsuo and K.Akutsu, 1999, RTRI rport, Vol.13, No.10, pp.31-34
  2. 小野純郎,'鐵道のスピ一ドアップ",日本鐵道運轉協會,1996
  3. 小林 寶 外 3名, 新幹線列車トンネル走行時の車外,車內壓 變動解析,日本機械學會論文集B, 61卷591考, 1995, pp256-262
  4. 新孫子 博 外 3名, '快適性向上を日指した空調システム', J-rail96, 1996, pp.287-290
  5. 原 朝茂, 高速でトンネルに突人する場合に列卓に作用する 空氣力,日本機械學會論文集B, 26卷171号, 1960, pp.1551-1586
  6. 남성원, '터널에서의 고속 철도 압력 특성에 관한 이론적 해석', 대한기계학회 논문집 투고중