콘칼로리미터를 이용한 내장판용 복합재료의 화재특성

Fire Characteristics of Composites for Interior Panels Using Cone calorimeter

  • 이철규 (한국철도기술연구원 철도환경연구그룹) ;
  • 정우성 (한국철도기술연구원 철도환경연구그) ;
  • 이덕희 (한국철도기술연구원 철도환경연구그룹)
  • 발행 : 2004.03.01

초록

Composite materials were used widely due to merit of light weight, low maintenance cost and easy installation. But it is the cause of enormous casualties to men and properties because of weak about the fire. Particularly, it is more serious in case of subway train installed composite materials. For this reason, experimental comparison has been done fur measuring heat release rate(H.R.R) and smoke production rate(S.P.R) of interior panels of electric motor car using cone calorimeter. A high radiative heat flux of 50kW/㎡ was used to bum out all materials and to simulate the condition of fully developed fire case in the tests. It was observed that Heat Release Rate and Smoke Production Rate curves were dependent on the kinds of the interior materials. From the heat release rate curves, the sustained ignition time, peak heat release rate and total heat release rate were deduced, These data are useful in classifying the materials by calculating two parameters describing the possibility to flashover.

키워드

참고문헌

  1. R. D. Peacock, R. W. Bukowski and S. H. Markos, Evaluation of Passenger Train Car Materials in the Cone Calorimeter, Fire Mater., 23, 53-62(1999) https://doi.org/10.1002/(SICI)1099-1018(199903/04)23:2<53::AID-FAM669>3.0.CO;2-I
  2. Federal Railroad Administration, Rail Passenger Equipment; Reissuance of Guidelines for Selection materials to Improve Their Fire Safety Characteristics, Federal Register, Vol.49, No.217, 44052-44584(1984)
  3. Urban Mass Trasportation Administration, Recommended Fire Safety Practices for Rail Transit Materials Selection, Federal Register; Vol.49, No.158(1984)
  4. National Fire Protection Association, NFPA 130, Standard for Fixed Guideway Transit Systems, 1990 edition, NFPA, Quincy, MA(1990)
  5. A Mekjian, Fire Hardened Composites for Improved Safety, INTERNATIONAL SAMPE SYMPOSIUM AND EXHIBITION, 45, 1204-1213(2000)
  6. 이근원, 김관응, 콘칼로리미터를 이용한 플라스틱 단열재의 화재특성, J. Korean Institute of Fire Sci. & Eng. Vol.17, No.1 (2003)
  7. ISO 5660-2, reaction-to-fire tests-Heat release, smoke production and mass loss rate-Part 2. Smoke production rate(dynamic measurement)
  8. T. L. Graham, G. M. Makhvilade and J. P. Roberts, On the Theory Flashover Development, Fire Safety Journal, Vol.25, 229-259( 1995) https://doi.org/10.1016/0379-7112(95)00049-6
  9. R. D. Peacock et. aI., Defining flashover for fire hazard calculation, Fire Safety Journal, Vol.32, 331-345(1999) https://doi.org/10.1016/S0379-7112(98)00048-4