Three methods for VOCs emissions control in indoor air are reduction at the source, ventilation between indoor and outdoor, and removal. The best alternative should be to replace highly emitting sources with sources having low emissions, but the pertinent information on VOCs is not always available from manufactures. Other ways of improving indoor air quality are needed. It is to increase the outside fresh-air flow to dilute the pollutants, but this method would generally provide only a dilution effect without destruction in residence. An ideal alternative to existing technologies would be a chemical oxidation process able to treat large volumes of slightly contaminated air at normal temperature without additional oxidant such as ozone generator and ion generator. Photocatalytic oxidation(PCO) represents such a process. It is characterized by a surface reaction assisted by light radiation inducing the formation of superoxide, hydroperoxide anions, or hydroxyl radicals, which are powerful oxidants. In comparison with other VOCs removal methods, PCO offers several advantages. The purpose of this study was to explore the possibilities for photocatalytic purification of slightly contaminated indoor air by using visible light such as flurescent visible light(FVL). In this study, a PCO of relatively concentrated benzene using common FVL lamps was investigated as batch type and total volatile organic compounds(TVOCs) using a common FVL lamp and penetrated sun light over window. The results of this study shown the possibility of TiO$_2$ photocatalyst application in the area of indoor air quality control.

Keywords

References

  1. Molhave, L. and Krzyanowski, M. : The right to healthy indoor air: status by 2002. Indoor Air, 13, 50-53, 2003 https://doi.org/10.1034/j.1600-0668.13.s.6.7.x
  2. Jones, A. P. : Indoor air quality and health. Atmospheric Environment, 33, 4535-4564, 1999 https://doi.org/10.1016/S1352-2310(99)00272-1
  3. US EPA : Unfinished business: a comparative assessment of environmental problems. EPA report EPA-230/2-87-025, 1987
  4. US EPA : Characterizing air emissions from indoor sources. EPA Report EPA/600/F-95 /005, 1995
  5. Vincent, D., Annesi, I., Festy, B. and Lambrozo, J. : Ventilation system, indoor air quality, and health out-comes in parisian modem office workers. Environ-mental Research, 75, 100-112, 1997 https://doi.org/10.1006/enrs.1997.3764
  6. Skillas, G., Huglin, C. and Siegmann, H. C. : Deter-mination of air exchange rates of rooms and deposition factors for fine panicles by means of photoelectric aerosol sensors, Indoor Built Environment, 8, 246-254, 2000
  7. Yang, W. H., Lee, K. Y. and Chung, M. H. : Char-acterization of indoor air quality using multiple mea-surements of nitrogen dioxide. Indoor Air, In Press, 2004
  8. Sparks, L. E., Molhave, L. and Dueholm, S. : Source testing and data analysis for exposure and risk assess-ment of indoor pollutant sources. ASTM STP 1287, American Society for Testing and Materials, 367-375, 1996
  9. 김신도 : 실내공기질 관리 및 측정. 한국대기환경학회 실내공기질 분과회 세미나, 102-115, 2003
  10. Bae, H., Yang, W. and Chung, M. : Potential exposureand traffic contribution to indoor air quality of shoe-stalls near busy road in Korea. The Science of the Total Environment, 323, 99-105, 2004 https://doi.org/10.1016/j.scitotenv.2003.09.033
  11. Spicer, C. W., Coutant, R. W., Ward, G. F. and Joseph, D. W. : Rates and mechanism of $NO_2$ removal from indoor air by residential materials. Environmental International, 15, 643-654, 1989 https://doi.org/10.1016/0160-4120(89)90087-1
  12. Jacoby, W. A., Blake, D. M., Fennell, J. A., Boulter, J. E., Vargo, L. M., George, M. C. and Dolberg, S. K. : Heterogeneous photocatalysis for control of volatile organic compounds in indoor air. Journal of the Air & Waste Management Association, 46, 891-898, 1996 https://doi.org/10.1080/10473289.1996.10467525
  13. Bhowmic, K. M. and Semmens, M. J. :Batch studies on closed loop air stripping process. Water Res., 28(9), 2011-2020, 1995 https://doi.org/10.1016/0043-1354(94)90176-7
  14. Fu, X., Zeltner, W. A. and Anderson. M. A. : The gas-phase photocatalytic mineralization of benzene on porous titania-based catalysts, Applied CataIysis B, Environment, 6, 209-224, 1995 https://doi.org/10.1016/0926-3373(95)00017-8
  15. 장성기 : 실내공기질 공정시험방법 작성 방향. 대한주택공사 주택도시 연구원 2003년 겨울호, 59-69, 2003
  16. 이병용, 김성욱, 정석진 : VOC 물질중 에탄올 광분해 반응을 위한 Ti$O_2$,촉매의 제조 변수 고찰. 한국대기환경학회, 17(4), 363-370, 2001
  17. Matralis, H. K., Ciardelli, M., Ruwet, M. and Grange, P. : Vanadia catalysts supported on mixed Ti$O_2$-A$l_2O_3$ supports: Effect of composition on the structure and acidity. Journal of Catalysis, 157, 368-379, 1995 https://doi.org/10.1006/jcat.1995.1302
  18. Yamashita, H., Ichihashi, Y., Harada, M., Stewart, G., Fox, M. A. and Anpo, M. : Photocatalytic degrada-tion of l-octanol on anchored titanium oxide and on Ti$O_2$ Power catalysts, Journal of Catalysis, 158, 97-101, 1996 https://doi.org/10.1006/jcat.1996.0010
  19. Obbe, T. N. and Brown, R. T. : Ti$O_2$ Photocatalysis for indoor air applications: effects of humidity and trace contaminant levels on the oxidation rates of formaldehyde, toluene, and 1,2-butadiene. Environ-mental Science & Technology, 29(5), 1223-1231, 1995 https://doi.org/10.1021/es00005a013
  20. Chapuis, Y., Klavana, D., Guy, C. and Kirchnerova, J. : Photocatalyst oxidation of volatile organic Com-pounds using fluorescent visible light. Journal of the Air & Waste Management Association, 52, 845-854, 2002 https://doi.org/10.1080/10473289.2002.10470816